Actions

Difference between revisions of "Turbine Compact Board Connectors"

From Zenitel Wiki

 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
{{APS}}
+
{{AEIPS}}
 
==Main PCB (A100C08121) ==
 
==Main PCB (A100C08121) ==
 
===Front===
 
===Front===
Line 65: Line 65:
 
The 5,3V output can deliver 200mA current maximum
 
The 5,3V output can deliver 200mA current maximum
  
See also [[Turbine Compact and MRBD]]
+
See also [[Adding additional relay(s) to a Zenitel IP Device]]
  
 
===Rear===
 
===Rear===

Latest revision as of 15:22, 23 June 2023

AEIPS.png

Main PCB (A100C08121)

Front

TCIS Connections 3.PNG


P1 RJ45 PoE port for 10/100 Mbit Ethernet connection.

The station can be powered from this port if the line supports Power over Ethernet (PoE).
TCIS Connections 4.PNG


P2 5-pin plug-on terminal for relay and external power

TCIS Connections 5.PNG


Pin 1/2: 24 VDC for external secondary power if PoE is not used. Pin 1 is positive.
Pin 3: COM relay (Common)
Pin 4: NO relay (Normally Open)
Pin 5: NC relay (Normally Closed)
  • Relay switching capacity: Max. 60 watt (Max voltage: 250VAC/220VDC. Max current: 2A)
  • Connectable conductors: 0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm².

P3 10-pin plug-on terminal for I/O's and Audio Line Out

TCIS Connections 6.PNG
Pin 1 5.3V (max. 200mA current)
Pin 2 GND
Pin 3 Button Input or LED Driver
Pin 4 Button Input or LED Driver
Pin 5 Button Input or LED Driver
Pin 6 Button Input or LED Driver
Pin 7 Button Input or LED Driver
Pin 8 Button Input or LED Driver
Pin 9 600 ohm balanced line out +
Pin 10 600 ohm balanced line out -


  • Connectable conductors: 0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm².

P4 Loudspeaker & Electret microphone

TCIS Connections 7.PNG


Pin 1: Speaker output +
Pin 2: Speaker output -
Pin 3: Electret Microphone +
Pin 4: Electret Microphone -
  • Connectable conductors: 0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm².
  • Recommended loudspeaker impedance: 8 ohms
Note icon To enable the electret microphone input when using a TKIS-2, the "Product Model And Accessory" must be set to "Kit" under Station Main > Main Settings in the web interface of the device.



Output Connectors + 1 relay

Connecting to the onboard relay. Extra LED controlled by output 1

The extra relay for any of the 6 I/O pins is connected as shown:

TurbineCompactOutputs.PNG

Most general purpose P-Channel MOSFET's should work. Recommended example: BSS84

The 5,3V output can deliver 200mA current maximum

See also Adding additional relay(s) to a Zenitel IP Device

Rear

TCIS Connections 8.PNG


J6 10-pin terminal for digital MEMS Microphone

TCIS Connections 9.PNG
Pin 1 Left mic select (Vdd)
Pin 2 Right mic select (GND)
Pin 3 Data
Pin 4 Data
Pin 5 Vdd 3.3V
Pin 6 Vdd 3.3V
Pin 7 CLK
Pin 8 CLK
Pin 9 GND
Pin 10 GND


Front Board (A100C08129)

Note icon Not applicable to TKIS-2 and TMIS-x


Front

TCIS Connections 10.PNG


Rear

TCIS Connections 11.PNG