Difference between revisions of "TKIS Connections"
From Zenitel Wiki
(→Input/Output Connections) |
|||
(7 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
+ | {{AEIPS}}This article describes the connections of the TKIS-2 kit. | ||
+ | |||
+ | The TKIS-2 kit is also used inside Zenitel IP Loudspeakers. | ||
+ | |||
[[File:TKIS-2_2.png|right|300px]] | [[File:TKIS-2_2.png|right|300px]] | ||
[[File:TCIS Connections 1.PNG|left|300px]] | [[File:TCIS Connections 1.PNG|left|300px]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
+ | |||
+ | |||
{| border="1" | {| border="1" | ||
Line 8: | Line 14: | ||
|Secondary Power || 24 VDC (16 – 48 V) secondary power is provided from an external adapter. | |Secondary Power || 24 VDC (16 – 48 V) secondary power is provided from an external adapter. | ||
|- | |- | ||
− | |Relays || | + | |Relays || Double Throw (SPDT) relay contact with 60W switching power. Max: 250VAC/220VDC, 2A, 60W |
|- | |- | ||
− | |Input/Output || 6 general purpose I/Os | + | |Input/Output || 6 general purpose I/Os. Each I/O can be configured as either input or 12mA LED driver output. |
|- | |- | ||
− | |Audio Line Out || A balanced 600 ohm audio line out | + | |Audio Line Out || A balanced 600 ohm audio line out suitable for e.g. external amplifier or induction loop amplifier |
|} | |} | ||
Line 36: | Line 42: | ||
===Input/Output Connections=== | ===Input/Output Connections=== | ||
There are 6 I/O connection options for the Turbine Compact Kit. | There are 6 I/O connection options for the Turbine Compact Kit. | ||
− | These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact | + | These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems. |
− | See also [[Turbine Compact | + | See also [[Turbine Compact series board connectors]] |
[[Category: Turbine Connections]] | [[Category: Turbine Connections]] |
Latest revision as of 10:22, 23 June 2023
This article describes the connections of the TKIS-2 kit.
The TKIS-2 kit is also used inside Zenitel IP Loudspeakers.
Ethernet/Power | 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line. |
Secondary Power | 24 VDC (16 – 48 V) secondary power is provided from an external adapter. |
Relays | Double Throw (SPDT) relay contact with 60W switching power. Max: 250VAC/220VDC, 2A, 60W |
Input/Output | 6 general purpose I/Os. Each I/O can be configured as either input or 12mA LED driver output. |
Audio Line Out | A balanced 600 ohm audio line out suitable for e.g. external amplifier or induction loop amplifier |
- When the Turbine Kit is connected to the network, its IP address is automatically obtained from a DHCP server or an IP address in the range 169.254.x.x will be assigned.
- To make the kit speak its IP address:
- connect a speaker to the speaker output
- connect a button to input 1
- press the button after startup
Network Connection
There is one RJ-45 port located on the Turbine Compact Kit that is used for PoE/LAN Ethernet connection.
Power Supply (optional)
The Turbine Compact Kit supports Power over Ethernet (PoE). If PoE is not available, the Turbine Compact Kit can be powered from a 24 VDC local power supply.
Input/Output Connections
There are 6 I/O connection options for the Turbine Compact Kit. These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.