Difference between revisions of "VSF-Fortitude6 8.1 Release Notes"
From Zenitel Wiki
(Created page with "* Previous Release - VSF-Fortitude6 8.0 Release Notes This document provides the release notes for VSF-Fortitude6 8.0 with incremental bug fix releases. The release notes...") |
(→Release info) |
||
(12 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
* Previous Release - [[VSF-Fortitude6 8.0 Release Notes]] | * Previous Release - [[VSF-Fortitude6 8.0 Release Notes]] | ||
+ | * Next Release - [[VSF-Fortitude6 8.2 Release Notes]] | ||
This document provides the release notes for VSF-Fortitude6 8.0 with incremental bug fix releases. The release notes for VSF-Fortitude6 8.1 describe new features, improvements and issues fixed after VSF-Fortitude6 8.0.3.2. | This document provides the release notes for VSF-Fortitude6 8.0 with incremental bug fix releases. The release notes for VSF-Fortitude6 8.1 describe new features, improvements and issues fixed after VSF-Fortitude6 8.0.3.2. | ||
Line 5: | Line 6: | ||
==Release info== | ==Release info== | ||
'''Name:''' VSF-Fortitude6 <br> | '''Name:''' VSF-Fortitude6 <br> | ||
− | '''Description:''' VSF-Fortitude6 is a firmware for [[ | + | '''Description:''' VSF-Fortitude6 is a firmware for [[Zenitel Devices based on iMX6|Zenitel devices based on the IMX6 processor]].. |
The firmware is delivered in two different files: | The firmware is delivered in two different files: | ||
Line 12: | Line 13: | ||
*vsff6-prod-8.1.3.x - Used in production- and recovery upgrades. | *vsff6-prod-8.1.3.x - Used in production- and recovery upgrades. | ||
− | '''Version:''' 8.1.3. | + | '''Version:''' 8.1.3.2<br> |
− | '''Date:''' 02. | + | '''Date:''' 02.05.2024 <br> |
'''Status:''' General Availability<br> | '''Status:''' General Availability<br> | ||
<br> | <br> | ||
− | =VSF-FORTITUDE6 8.1.3. | + | =VSF-FORTITUDE6 8.1.3.2= |
− | |||
==Fixed Issues== | ==Fixed Issues== | ||
− | === MTN- | + | === MTN-4420 Cyber security update=== |
− | + | A software update to mitigate a critical cyber security issue | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
<br> | <br> | ||
− | =VSF-FORTITUDE6 8. | + | =VSF-FORTITUDE6 8.1.3.1= |
− | |||
==Fixed Issues== | ==Fixed Issues== | ||
− | ===DS- | + | === DS-817 Zenitel Connect Pro 1.1 compatible=== |
+ | Compatible with Zenitel Connect Pro 1.1. No changes for ICX-AlphaCom, SIP and IC-EDGE mode. | ||
<br> | <br> | ||
− | =VSF-FORTITUDE6 8. | + | =VSF-FORTITUDE6 8.1.3.0= |
− | |||
== Improvements == | == Improvements == | ||
− | === MTN- | + | === MTN-4156 Added option for using Normally Closed switch on I/O Pins configured as input=== |
− | + | The default input configuration is Normally Open and the switch contact needs to close to activate the function. A new option “Input NC” has been added to the I/O Pin configuration, which inverts the default behavior and the function is activated on switch open. | |
+ | <br> | ||
− | ===MTN- | + | ==Fixed Issues== |
− | + | === MTN-435 User experience: Audio output level too low when in conversation with master stations=== | |
+ | Handset and Headset microphone level was too low according to standard voice level. The gain was increased gain with +10 dB so transmitted signal level reaches target level of -23 dBFS with “nominal voice input” | ||
− | === | + | === MTN-4346 User experience: Audio output level too low when in open duplex conversation with imx6 and im8 based devices=== |
− | + | The gain was increased after AEC but before the audio signal compander (with AGC function) so transmitted signal level reaches target level of -23 dBFS with “nominal voice input” | |
− | + | === MTN-4230 Fixed issue where audio is not heard when station is using SRTP=== | |
− | + | When stations are registered to a SIP server using TLS, Secure SIP and SRTP, audio was heard only on the caller side. This is now fixed, and audio can be heard on both sides. | |
− | |||
− | === MTN- | ||
− | |||
− | === MTN- | + | === MTN-4217 Allowing underscore in SNMP community string=== |
− | + | Underscore is now allowed in the SNMP community string. | |
− | === MTN- | + | === MTN-4213 Added configuration option to force network IGMP versions 2 or 3 on devices with on-board switch=== |
− | + | By default the IGMP version is automatically set by snooping the network traffic. | |
+ | If a device fails to detect the correct version and when it is known which version should be used, the IGMP version can be hard set by this configuration option. | ||
[[Category: Release notes]] | [[Category: Release notes]] |
Latest revision as of 09:05, 21 June 2024
- Previous Release - VSF-Fortitude6 8.0 Release Notes
- Next Release - VSF-Fortitude6 8.2 Release Notes
This document provides the release notes for VSF-Fortitude6 8.0 with incremental bug fix releases. The release notes for VSF-Fortitude6 8.1 describe new features, improvements and issues fixed after VSF-Fortitude6 8.0.3.2.
Contents
- 1 Release info
- 2 VSF-FORTITUDE6 8.1.3.2
- 3 VSF-FORTITUDE6 8.1.3.1
- 4 VSF-FORTITUDE6 8.1.3.0
- 4.1 Improvements
- 4.2 Fixed Issues
- 4.2.1 MTN-435 User experience: Audio output level too low when in conversation with master stations
- 4.2.2 MTN-4346 User experience: Audio output level too low when in open duplex conversation with imx6 and im8 based devices
- 4.2.3 MTN-4230 Fixed issue where audio is not heard when station is using SRTP
- 4.2.4 MTN-4217 Allowing underscore in SNMP community string
- 4.2.5 MTN-4213 Added configuration option to force network IGMP versions 2 or 3 on devices with on-board switch
Release info
Name: VSF-Fortitude6
Description: VSF-Fortitude6 is a firmware for Zenitel devices based on the IMX6 processor..
The firmware is delivered in two different files:
- vsff6-8.1.3.x - Used for standard in-field upgrades
- vsff6-prod-8.1.3.x - Used in production- and recovery upgrades.
Version: 8.1.3.2
Date: 02.05.2024
Status: General Availability
VSF-FORTITUDE6 8.1.3.2
Fixed Issues
MTN-4420 Cyber security update
A software update to mitigate a critical cyber security issue
VSF-FORTITUDE6 8.1.3.1
Fixed Issues
DS-817 Zenitel Connect Pro 1.1 compatible
Compatible with Zenitel Connect Pro 1.1. No changes for ICX-AlphaCom, SIP and IC-EDGE mode.
VSF-FORTITUDE6 8.1.3.0
Improvements
MTN-4156 Added option for using Normally Closed switch on I/O Pins configured as input
The default input configuration is Normally Open and the switch contact needs to close to activate the function. A new option “Input NC” has been added to the I/O Pin configuration, which inverts the default behavior and the function is activated on switch open.
Fixed Issues
MTN-435 User experience: Audio output level too low when in conversation with master stations
Handset and Headset microphone level was too low according to standard voice level. The gain was increased gain with +10 dB so transmitted signal level reaches target level of -23 dBFS with “nominal voice input”
MTN-4346 User experience: Audio output level too low when in open duplex conversation with imx6 and im8 based devices
The gain was increased after AEC but before the audio signal compander (with AGC function) so transmitted signal level reaches target level of -23 dBFS with “nominal voice input”
MTN-4230 Fixed issue where audio is not heard when station is using SRTP
When stations are registered to a SIP server using TLS, Secure SIP and SRTP, audio was heard only on the caller side. This is now fixed, and audio can be heard on both sides.
MTN-4217 Allowing underscore in SNMP community string
Underscore is now allowed in the SNMP community string.
MTN-4213 Added configuration option to force network IGMP versions 2 or 3 on devices with on-board switch
By default the IGMP version is automatically set by snooping the network traffic. If a device fails to detect the correct version and when it is known which version should be used, the IGMP version can be hard set by this configuration option.