Difference between revisions of "TA-10"
From Zenitel Wiki
(→Configuration) |
|||
Line 17: | Line 17: | ||
==Configuration== | ==Configuration== | ||
− | [[File:TA-10 RCO map.PNG|right|400px|Logical RCO 11 is mapped to the relay of the TA-10 unit on station 118]] | + | [[File:TA-10 RCO map.PNG|right|400px|thumb|Logical RCO 11 is mapped to the relay of the TA-10 unit on station 118]] |
'''AlphaCom Mode''': | '''AlphaCom Mode''': | ||
* Use the [[AlphaPro]] tool, and go to '''Exchange & System''' > '''RCO''' | * Use the [[AlphaPro]] tool, and go to '''Exchange & System''' > '''RCO''' |
Revision as of 10:28, 3 February 2017
TA-10 is a Relay Module to be used with Turbine Industrial stations TFIE-1 and TFIE-2, and the Turbine kits TKIE-1 and TKIE-2.
Highlights
- Designed for use with Turbine Industrial stations TFIE-x, and the Turbine kits TKIE-x
- Fits inside the TFIE Industrial stations (Bracket included in the TFIE station)
- Dual high-power relays (DPDT)
- Up to 400VAC /48 VDC per relay
- Up to 6A current per relay
- Heavy-duty spring-loaded terminals with spare grounding terminals
- Powered by Turbine Industrial stations (TFIE-x) or Turbine Extended Kit (TKIE-x)
Connection
- Use the cable that comes with the TA-10, and connect one end to the Turbine Extended Board (Connector J2), and the other end to the TA-10 board as indicated in the drawing below
Configuration
AlphaCom Mode:
- Use the AlphaPro tool, and go to Exchange & System > RCO
- The two relays must be mapped in the RCO table as pin 9 and pin 10
- See RCO - Remote Control Output for more details
SIP or Pulse mode:
- Log on to the web interface of the station
- Select SIP Configuration > Relay Settings, select Relay 3 or Relay 4, and configure which event should operate the relay
- See Relay Settings for more details
Dimensions
- Dimensions (WxHxD): 100 x 50 x 40 mm