INCA Station Kit Restore Factory Defaults: Difference between revisions
From Zenitel Wiki
(Created page with "== Restore to Factory Default for IP Stations without Display and Key == * IP Speaker - 1401002100/IP Horn Loudspeaker - 1401002500|1...") |
|||
| Line 1: | Line 1: | ||
Restore to Factory Default for IP Stations without Display and Key | |||
* IP Speaker - [[IP Ceiling Loudspeaker - 1401002100|1401002100]]/[[IP Horn Loudspeaker - 1401002500|1401002500]] | * IP Speaker - [[IP Ceiling Loudspeaker - 1401002100|1401002100]]/[[IP Horn Loudspeaker - 1401002500|1401002500]] | ||
* IP Heavy Duty - [[IP Heavy Duty Station - 1008072200|1008072200]] | * IP Heavy Duty - [[IP Heavy Duty Station - 1008072200|1008072200]] | ||
* IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]] | * IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]] | ||
The procedure can be used on the IP Substation Kit - 1008090200 an on the IP Master Station Kit - 1008093000. | The procedure can be used on the IP Substation Kit - 1008090200 an on the IP Master Station Kit - 1008093000. | ||
The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP. | The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP. | ||
Connect a push button ('''KEY1''') between pin 1 and 4 on the P4 connector. | |||
[[File:Load Defaults without KEY.PNG|left]] | [[File:Load Defaults without KEY.PNG|left]] | ||
<br style="clear:both;" /> | |||
-------- | |||
=== Restore with Static IP === | |||
# While pressing the button, power up the station kit. | |||
# When the station kit LED starts blinking, release the button '''after exactly 2 blinks'''. | |||
# Let the LED blink for '''exactly 2 more times''', then press the button again. | |||
# Keep the button pressed until the LED '''blinks fast 2 times''' indicating a successful reset with static IP. | |||
# Release the button and the station kit will restart with the factory default settings. | |||
<u>'''Factory default values:'''</u> | |||
* Station IP address: '''169.254.1.100''' | |||
* AlphaCom IP address: '''169.254.1.5''' | |||
* Username: '''admin''' (Software 01.06 and earlier: '''ADMIN''') | |||
* Password: '''alphaadmin''' (Software 01.06 and earlier: '''alphacom''') | |||
------ | |||
=== Restore with Activated DHCP === | |||
The DHCP option is available from software version 01.07. | |||
# While pressing the button, power up the station kit. | |||
# When the station kit LED starts blinking, release the button '''after exactly 2 blinks'''. | |||
# Let the LED blink for '''exactly 4 more times''', then press the button again. | |||
# Keep the button pressed until the LED '''blinks fast 4 times''' indicating a successful reset with activated DHCP. | |||
# Release the button and the station kit will restart with the factory default settings. | |||
'''Factory default values:''' | |||
* Station IP address: (determined by DHCP server) | |||
* AlphaCom IP address: '''169.254.1.5''' | |||
* Username: '''admin''' (Software 01.06 and earlier: '''ADMIN''') | |||
* Password: '''alphaadmin''' (Software 01.06 and earlier: '''alphacom''') | |||
[[Category: INCA - Restore Factory Defaults and Software Upgrade]] | [[Category: INCA - Restore Factory Defaults and Software Upgrade]] | ||
Revision as of 10:52, 24 October 2016
Restore to Factory Default for IP Stations without Display and Key
- IP Speaker - 1401002100/1401002500
- IP Heavy Duty - 1008072200
- IP Substation Kit - 1008090200
The procedure can be used on the IP Substation Kit - 1008090200 an on the IP Master Station Kit - 1008093000.
The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP.
Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.
Restore with Static IP
- While pressing the button, power up the station kit.
- When the station kit LED starts blinking, release the button after exactly 2 blinks.
- Let the LED blink for exactly 2 more times, then press the button again.
- Keep the button pressed until the LED blinks fast 2 times indicating a successful reset with static IP.
- Release the button and the station kit will restart with the factory default settings.
Factory default values:
- Station IP address: 169.254.1.100
- AlphaCom IP address: 169.254.1.5
- Username: admin (Software 01.06 and earlier: ADMIN)
- Password: alphaadmin (Software 01.06 and earlier: alphacom)
Restore with Activated DHCP
The DHCP option is available from software version 01.07.
- While pressing the button, power up the station kit.
- When the station kit LED starts blinking, release the button after exactly 2 blinks.
- Let the LED blink for exactly 4 more times, then press the button again.
- Keep the button pressed until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
- Release the button and the station kit will restart with the factory default settings.
Factory default values:
- Station IP address: (determined by DHCP server)
- AlphaCom IP address: 169.254.1.5
- Username: admin (Software 01.06 and earlier: ADMIN)
- Password: alphaadmin (Software 01.06 and earlier: alphacom)