Difference between revisions of "INCA Station Kit Restore Factory Defaults"
From Zenitel Wiki
(→Restore with Activated DHCP) |
|||
Line 2: | Line 2: | ||
* IP Master Station Kit [[IP Master Station Kit - 1008093000|100809300]] | * IP Master Station Kit [[IP Master Station Kit - 1008093000|100809300]] | ||
* IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]] | * IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]] | ||
− | |||
* IP Heavy Duty - [[IP Heavy Duty Station - 1008072200|1008072200]] | * IP Heavy Duty - [[IP Heavy Duty Station - 1008072200|1008072200]] | ||
Revision as of 09:13, 1 November 2016
Restore to Factory Default for IP Stations without Display and Key:
- IP Master Station Kit 100809300
- IP Substation Kit - 1008090200
- IP Heavy Duty - 1008072200
For IP Master Station kits with display, see: INCA Display Station Restore Factory Defaults
The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP.
Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.
Restore with Static IP
- While pressing the button, power up the station kit.
- When the station kit LED starts blinking, release the button after exactly 2 blinks.
- Let the LED blink for exactly 2 more times, then press the button again.
- Keep the button pressed until the LED blinks fast 2 times indicating a successful reset with static IP.
- Release the button and the station kit will restart with the factory default settings.
Factory default values | |
---|---|
Station Mode | Pulse |
Station IP address | 169.254.1.100 |
AlphaCom IP address | 169.254.1.5 |
Username* | admin |
Password* | alphaadmin |
* Software 01.06 and earlier: ADMIN/alphacom)
Restore with Activated DHCP
The DHCP option is available from software version 01.07.
- While pressing the button, power up the station kit.
- When the station kit LED starts blinking, release the button after exactly 2 blinks.
- Let the LED blink for exactly 4 more times, then press the button again.
- Keep the button pressed until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
- Release the button and the station kit will restart with the factory default settings.
Factory default values | |
---|---|
Station Mode | Pulse |
Station IP address | determined by DHCP server |
AlphaCom IP address | 169.254.1.5 |
Username* | admin |
Password* | alphaadmin |
* Software 01.06 and earlier: ADMIN/alphacom)