− | Faults in the ENA Amplifier can be reported to a display station, e.g. to IP Desktop, DualDisplay or CRMV station. | + | Faults in the ENA Amplifier can be reported to a display station, e.g. to [[IP Desktop Master Station - 1008001000|IP Desktop]], [[IP Dual Display Station - 1008007000|DualDisplay]] or [[CRM V - Control Room Master|CRMV station]]. |
− | In | + | In order to have one common event for all ENA amplifiers, include the amplifiers in a [[UDP group|UDP Group]]. Here UDP Group 3 is used as an example. |
In AlphaPro, select '''Exchange & System''' > '''Events''', and '''Insert''' a new event with the following properties: | In AlphaPro, select '''Exchange & System''' > '''Events''', and '''Insert''' a new event with the following properties: |
Revision as of 11:29, 12 April 2018
Faults in the ENA Amplifier can be reported to a display station, e.g. to IP Desktop, DualDisplay or CRMV station.
In order to have one common event for all ENA amplifiers, include the amplifiers in a UDP Group. Here UDP Group 3 is used as an example.
In AlphaPro, select Exchange & System > Events, and Insert a new event with the following properties:
Action Command:
IF %chg(1,0) $STM %1.ref L164 U%op(70,+,%sev) '(%1.dir) %2.nam' STOP ENDIF $CANM %1.ref L164 NM253 U%op(70,+,%sev)