Difference between revisions of "IND - Indicator control for CRMIV LEDs, buzzer etc."
From Zenitel Wiki
Line 30: | Line 30: | ||
! style="background:#ffdead;" width="300" |IND-type | ! style="background:#ffdead;" width="300" |IND-type | ||
! style="background:#ffdead;" width="80" |[state] | ! style="background:#ffdead;" width="80" |[state] | ||
+ | |- | ||
+ | | align=center valign="top"| '''CRM V and IP Flush Master (8024)''' | ||
+ | |align=center valign="top"|1 - 552 | ||
+ | |valign="top" |1-100 = DAK-key number | ||
+ | |valign="top" |1 = Red LED <br> | ||
+ | 2 = Green LED <br> | ||
+ | |valign="top" |1 = continuous (low priority) <br> | ||
+ | 2 = slow flash (medium priority) <br> | ||
+ | 3 = fast flash (high priority) <br> | ||
+ | |valign="top" |ON or OFF | ||
|- | |- | ||
| align=center valign="top"| '''IP Substation (8022)''' | | align=center valign="top"| '''IP Substation (8022)''' | ||
Line 58: | Line 68: | ||
|valign="top" |ON or OFF | |valign="top" |ON or OFF | ||
|- | |- | ||
− | | align=center valign="top"| ''' | + | | align=center valign="top"| '''ENA Amplifier''' |
|align=center valign="top"|1 - 552 | |align=center valign="top"|1 - 552 | ||
− | |valign="top" | | + | |valign="top" |513 = Fault LED<br>513 = Alarm LED<br>513 = Disabled LED |
− | |valign="top" |1 | + | |valign="top" |Always "1"<br> |
− | |||
|valign="top" |1 = continuous (low priority) <br> | |valign="top" |1 = continuous (low priority) <br> | ||
2 = slow flash (medium priority) <br> | 2 = slow flash (medium priority) <br> |
Revision as of 14:43, 27 February 2019
The IND (INDication) or GIND action is used in the Event Handler for sending commands to a station or a group of stations. The commands are sent as display data. The following stations are currently supporting the IND command:
- IP Flush Master and CRM V: Control the LED's in the DAK keys
- CRM IV: Control the LED's in the DAK keys, the internal buzzer or relay, and the backlight of the display
- DualDisplay station: Control the video-state of the DAK-display
- Priscom station: Control the outputs used for lamps, cell light, call LED and spare output
- IP-ARIO: Control the Error LED and the Radio LED
- IP Substation: Control relay and spare output
- Turbine station: Control relay and the 6 additional outputs
- ECPIR-3P and EBMDR-8 module
- ENA Amplifiers: Fault, Alarm and Disabled LEDs
Command syntax
IND <station phys.no> <output> <LED no/buzzer> <Ind-type> [state]
|
GIND <group ind> <output> <LED no/buzzer> <Ind-type> [state]
|
- <group ind> is the AlphaCom group index number 1-250. (Not the group directory number)
There must be a space between the command parameters.
Parameter description:
Station/Parameter | phys. number | output | LED no/buzzer | IND-type | [state] |
---|---|---|---|---|---|
CRM V and IP Flush Master (8024) | 1 - 552 | 1-100 = DAK-key number | 1 = Red LED 2 = Green LED |
1 = continuous (low priority) 2 = slow flash (medium priority) |
ON or OFF |
IP Substation (8022) | 1 - 552 | 1 = Relay 2 = Spare output |
Always "1" |
1 = continuous (low priority) 2 = slow flash (medium priority) |
ON or OFF |
Turbine station | 1 - 552 | 17 = Relay 11-16 = Spare outputs See note below! |
Always "1" |
1 = continuous (low priority) 2 = slow flash (medium priority) |
ON or OFF |
ECPIR-3P | 1 - 552 | 513 = Fault LED Requires AMC 13.1.x.x |
Always "1" |
1 = continuous (low priority) 2 = slow flash (medium priority) |
ON or OFF |
ENA Amplifier | 1 - 552 | 513 = Fault LED 513 = Alarm LED 513 = Disabled LED |
Always "1" |
1 = continuous (low priority) 2 = slow flash (medium priority) |
ON or OFF |
DualDisplay | 1 - 552 | 1-100 = The DAK-key line | Always "1" | Video-state of the DAK-display:
|
ON or OFF |
IP-ARIO | 1 - 552 | 1 = Radio LED 2 = Error LED |
1 = Red LED (Radio and Error) 2 = Green LED (Radio LED only) |
1 = continuous (low priority) 2 = slow flash (medium priority) |
ON or OFF |
PrisCom | 1 - 552 | 1 - 4 = Lamp outputs 5 - 6 = Spare outputs 7 = Relay (Cell light) 8 = Call LED |
Always "1" | Output state:
|
ON or OFF |
CRM IV | 1 - 552 | 1-100 = DAK-key number 1023 = Buzzer 1024 = Display backlight |
DAK-key:
Buzzer:
Display backlight:
|
DAK LED's:
Buzzers:
Display backlight:
|
ON or OFF |
The state parameter is optional. If nothing is entered in this field, the indication is switched on/off along with the event. By entering OFF, for example, you can set an indication to turn off when the event turns on.
Note on Turbine: The output numbers to use depend on the AMC software version.
- AMC version 11.2.3.9 and earlier: Use IND numbers 1 - 7
- AMC version 11.2.3.10: Outputs cannot be controlled by IND command
- AMC version 11.2.3.11 and later: Use IND numbers 11 - 17
Example
IND 2 23 2 3 ON = Station 2, key 23, turn green led, fast flashing, ON
Related articles
- RCO - Remote Control Output
- $SET_IPRCO: This data command can be used to activate Remote Control Outputs on IP Stations and IPARIO without having to define the RCO's in the RCO table.