Actions

Touchless sensor (w/ backbox): Difference between revisions

From Zenitel Wiki

Line 40: Line 40:


=== Configuration on ICX-AlphaCom ===
=== Configuration on ICX-AlphaCom ===
TO configure the ...:
# Select '''Users & Stations'''
# '''Select the intercom station''' with the touchless sensor connected
# Open the '''DAK''' window
# Select the tab '''DAK 11-20'''
# On DAK 11 (=input 1) enter the '''directory number''' to call when the input is activated


[[File:TouchLess ICX.png|thumb|500px|left|Input 1 configured to call number 13 when triggered]]
[[File:TouchLess ICX.png|thumb|500px|left|Input 1 configured to call number 13 when triggered]]

Revision as of 14:22, 17 March 2021

Touchless sensor, item 2390020100

The Touchless sensor (item 2390020100) is an IR-sensor that connects to Turbine Compact stations and is used to activate calls with gesture recognition instead of pressing the call button.

Highlights

  • Input Voltage: 5V
  • Available contacts: Normally Open & Normally Closed
  • Sensor active time: 0,5 secs
  • Operating distance: 15cm
  • IP66

Connections

Connections are made to the switch using the supplied 5 pin plug.
Correct orientation of the plug is ensured by the connector locating guides.

Color code

  • Red - +5 Volt supply
  • Brown - 0 Volt supply
  • Green - Normally Closed
  • Blue - Common
  • Purple - Normally Open

Typical Application

Touchless sensor - general wiring


Use Case Examples

Touchless sensor wired to Input 1 on a Turbine station:

Touchless sensor - wiring example


Configuration on IC-Edge

To configure the Input select Edge Controller > System Configuration > Direct Access Keys.
Select Show/Hide Settings on the station you want to configure:

Input 1 configured to call number 13 when triggered


Configure the Input to Call To a directory number when activated.

More details can be found on Direct Access Key Settings.

Configuration on ICX-AlphaCom

TO configure the ...:

  1. Select Users & Stations
  2. Select the intercom station with the touchless sensor connected
  3. Open the DAK window
  4. Select the tab DAK 11-20
  5. On DAK 11 (=input 1) enter the directory number to call when the input is activated


Input 1 configured to call number 13 when triggered



Configuration of Inputs and Direct Access Keys (DAK) are done in AlphaPro.
Detailed information is found under DAK programming.

MediaWiki spam blocked by CleanTalk.