Difference between revisions of "Touchless sensor (w/ backbox)"
From Zenitel Wiki
(→Configuration in ICX-AlphaCom) |
(→Configuration in ICX-AlphaCom) |
||
Line 46: | Line 46: | ||
# Open the '''DAK''' window | # Open the '''DAK''' window | ||
# Select the tab '''DAK 11-20''' | # Select the tab '''DAK 11-20''' | ||
− | # On DAK 11 (= input 1) enter the '''directory number''' to call when the input is activated | + | # On DAK 11 (= input 1*) enter the '''directory number''' to call when the input is activated |
[[File:TouchLess ICX.png|thumb|700px|left|Input 1 configured to call number 13 when triggered]] | [[File:TouchLess ICX.png|thumb|700px|left|Input 1 configured to call number 13 when triggered]] |
Revision as of 14:28, 17 March 2021
The Touchless sensor (item 2390020100) is an IR-sensor that connects to Turbine Compact stations and is used to activate calls with gesture recognition instead of pressing the call button.
Contents
Highlights
- Input Voltage: 5V
- Available contacts: Normally Open & Normally Closed
- Sensor active time: 0,5 secs
- Operating distance: 15cm
- IP66
Connections
Connections are made to the switch using the supplied 5 pin plug.
Correct orientation of the plug is ensured by the connector locating guides.
Color code
- Red - +5 Volt supply
- Brown - 0 Volt supply
- Green - Normally Closed
- Blue - Common
- Purple - Normally Open
Typical Application
Use Case Examples
Touchless sensor wired to Input 1 on a Turbine station:
Configuration on IC-Edge
- To configure the Input select Edge Controller > System Configuration > Direct Access Keys.
- Select Show/Hide Settings on the station you want to configure.
- Configure the Input to Call To, and enter the directory number to call when activated.
More details can be found on Direct Access Key Settings.
Configuration in ICX-AlphaCom
To configure the input to call a preconfigured number:
- Select Users & Stations
- Select the intercom station to which the touchless sensor is connected
- Open the DAK window
- Select the tab DAK 11-20
- On DAK 11 (= input 1*) enter the directory number to call when the input is activated
(*) Input 1 - 6 is mapped to DAK 11 - 16.
More information is found under DAK programming.