− | One can use the [[Faulty Station Line (Event Type)|Faulty Station Line - OFF]] together with %prci to read the status of the inputs when a device registers to the ICX-AlphaCom. However, one have to | + | One can use the [[Faulty Station Line (Event Type)|Faulty Station Line - OFF]] together with %prci to read the status of the inputs when a device registers to the ICX-AlphaCom. However, one have to insert a small delay (SET TIMER|$ST) of approx. 5 seconds from the device registers to the inputs are read. |
Revision as of 09:30, 18 November 2024
The %prci macro is used in the Event Handler to check state of a physical input on a Zenitel IP Device.
Syntax
%prci(station,input_no)
Return 1 (active) or 0 (not active) state of a physical input
- station: Physical number 1 - 552
- input_no: Input number 1 - 8
Examples
%prci(5,1) - Return state of input 1 on station 5
Notes
One can use the Faulty Station Line - OFF together with %prci to read the status of the inputs when a device registers to the ICX-AlphaCom. However, one have to insert a small delay (SET TIMER|$ST) of approx. 5 seconds from the device registers to the inputs are read.