MPC Data Protocol: Difference between revisions
From Zenitel Wiki
| Line 1: | Line 1: | ||
The AlphaCom supports a subset of the MPC data protocol used with the classic Stentofon [[TouchLine]] exchanges. As it allows control of the AlphaCom exchange by mapping MPC commands to AlphaCom commands one-to-one it can be thought of as a variant of the simple link layer, but only for single-exchange (not AlphaNet) applications. | The AlphaCom supports a subset of the MPC data protocol used with the classic Stentofon [[TouchLine]] exchanges. As it allows control of the AlphaCom exchange by mapping MPC commands to AlphaCom commands one-to-one it can be thought of as a variant of the simple link layer, but only for single-exchange (not AlphaNet) applications. | ||
Revision as of 20:53, 19 June 2007
The AlphaCom supports a subset of the MPC data protocol used with the classic Stentofon TouchLine exchanges. As it allows control of the AlphaCom exchange by mapping MPC commands to AlphaCom commands one-to-one it can be thought of as a variant of the simple link layer, but only for single-exchange (not AlphaNet) applications.
The output is broadcast of exchange events like dialled digits, station busy/free, connection and transfers. Note that it’s possible to send additional data strings from the AlphaCom’s Event Handler on this port also.
The AlphaCom supports a subset of the MPC Data Protocol for backward compatibility. This allowed some TouchLine generation equipment like PNCI, MLH and CRM to be used with the AlphaCom.
Availability
AlphaCom has supported a serial data port which outputs TouchLine formatted output messages since AMC 03.00. From software AMC 07.60, a limited subset of TouchLine input commands are supported also.