== Restore to Factory Default for IP Stations without Display and Key ==
+
Restore to Factory Default for IP Stations without Display and Key
 
* IP Speaker - [[IP Ceiling Loudspeaker - 1401002100|1401002100]]/[[IP Horn Loudspeaker - 1401002500|1401002500]]
 
* IP Speaker - [[IP Ceiling Loudspeaker - 1401002100|1401002100]]/[[IP Horn Loudspeaker - 1401002500|1401002500]]
 
* IP Heavy Duty - [[IP Heavy Duty Station - 1008072200|1008072200]]
 
* IP Heavy Duty - [[IP Heavy Duty Station - 1008072200|1008072200]]
 
* IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]]
 
* IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]]
 
The procedure can be used on the IP Substation Kit - 1008090200 an on the IP Master Station Kit - 1008093000.
 
The procedure can be used on the IP Substation Kit - 1008090200 an on the IP Master Station Kit - 1008093000.
<br/>
+
 
The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP.<br/>
+
The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP.
 +
 
 +
Connect a push button ('''KEY1''') between pin 1 and 4 on the P4 connector.
 +
 
 
[[File:Load Defaults without KEY.PNG|left]]
 
[[File:Load Defaults without KEY.PNG|left]]
* Connect a push button ('''KEY1''') between pin 1 and 4 on the P4 connector.
+
<br style="clear:both;" />
* Press the button, and power up the substation
+
 
* Keep the button pressed. Release the call button after exactly 2 blinks of the LED
+
--------
* Let the LED blink for exactly 2 (Static IP) or 4 times (DHCP), then press the button again  
+
 
* Keep the button pressed until it confirms successful factory reset by 2 (Static IP) or 4 (DHCP) fast blinks of the LED
+
=== Restore with Static IP ===
 +
# While pressing the button, power up the station kit.
 +
# When the station kit LED starts blinking, release the button '''after exactly 2 blinks'''.
 +
# Let the LED blink for '''exactly 2 more times''', then press the button again.
 +
# Keep the button pressed until the LED '''blinks fast 2 times''' indicating a successful reset with static IP.
 +
# Release the button and the station kit will restart with the factory default settings.
 +
 
 +
<u>'''Factory default values:'''</u>
 +
* Station IP address: '''169.254.1.100'''
 +
* AlphaCom IP address: '''169.254.1.5'''
 +
* Username: '''admin''' (Software 01.06 and earlier: '''ADMIN''')
 +
* Password: '''alphaadmin''' (Software 01.06 and earlier: '''alphacom''')
 +
 
 +
------
 +
 
 +
=== Restore with Activated DHCP ===
 +
The DHCP option is available from software version 01.07.
 +
# While pressing the button, power up the station kit.
 +
# When the station kit LED starts blinking, release the button '''after exactly 2 blinks'''.
 +
# Let the LED blink for '''exactly 4 more times''', then press the button again.
 +
# Keep the button pressed until the LED '''blinks fast 4 times''' indicating a successful reset with activated DHCP.
 +
# Release the button and the station kit will restart with the factory default settings.
 +
 
 +
'''Factory default values:'''
 +
* Station IP address: (determined by DHCP server)
 +
* AlphaCom IP address: '''169.254.1.5'''
 +
* Username: '''admin''' (Software 01.06 and earlier: '''ADMIN''')
 +
* Password: '''alphaadmin''' (Software 01.06 and earlier: '''alphacom''')
  
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]

Revision as of 10:52, 24 October 2016

Restore to Factory Default for IP Stations without Display and Key

The procedure can be used on the IP Substation Kit - 1008090200 an on the IP Master Station Kit - 1008093000.

The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP.

Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.

Load Defaults without KEY.PNG



Restore with Static IP

  1. While pressing the button, power up the station kit.
  2. When the station kit LED starts blinking, release the button after exactly 2 blinks.
  3. Let the LED blink for exactly 2 more times, then press the button again.
  4. Keep the button pressed until the LED blinks fast 2 times indicating a successful reset with static IP.
  5. Release the button and the station kit will restart with the factory default settings.

Factory default values:

  • Station IP address: 169.254.1.100
  • AlphaCom IP address: 169.254.1.5
  • Username: admin (Software 01.06 and earlier: ADMIN)
  • Password: alphaadmin (Software 01.06 and earlier: alphacom)

Restore with Activated DHCP

The DHCP option is available from software version 01.07.

  1. While pressing the button, power up the station kit.
  2. When the station kit LED starts blinking, release the button after exactly 2 blinks.
  3. Let the LED blink for exactly 4 more times, then press the button again.
  4. Keep the button pressed until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
  5. Release the button and the station kit will restart with the factory default settings.

Factory default values:

  • Station IP address: (determined by DHCP server)
  • AlphaCom IP address: 169.254.1.5
  • Username: admin (Software 01.06 and earlier: ADMIN)
  • Password: alphaadmin (Software 01.06 and earlier: alphacom)