Difference between revisions of "Touchless sensor (w/ backbox)"
From Zenitel Wiki
(→Configuration on IC-Edge) |
(→Configuration on ICX-AlphaCom) |
||
Line 40: | Line 40: | ||
=== Configuration on ICX-AlphaCom === | === Configuration on ICX-AlphaCom === | ||
+ | |||
+ | TO configure the ...: | ||
+ | # Select '''Users & Stations''' | ||
+ | # '''Select the intercom station''' with the touchless sensor connected | ||
+ | # Open the '''DAK''' window | ||
+ | # Select the tab '''DAK 11-20''' | ||
+ | # On DAK 11 (=input 1) enter the '''directory number''' to call when the input is activated | ||
+ | |||
[[File:TouchLess ICX.png|thumb|500px|left|Input 1 configured to call number 13 when triggered]] | [[File:TouchLess ICX.png|thumb|500px|left|Input 1 configured to call number 13 when triggered]] |
Revision as of 14:22, 17 March 2021
The Touchless sensor (item 2390020100) is an IR-sensor that connects to Turbine Compact stations and is used to activate calls with gesture recognition instead of pressing the call button.
Contents
Highlights
- Input Voltage: 5V
- Available contacts: Normally Open & Normally Closed
- Sensor active time: 0,5 secs
- Operating distance: 15cm
- IP66
Connections
Connections are made to the switch using the supplied 5 pin plug.
Correct orientation of the plug is ensured by the connector locating guides.
Color code
- Red - +5 Volt supply
- Brown - 0 Volt supply
- Green - Normally Closed
- Blue - Common
- Purple - Normally Open
Typical Application
Use Case Examples
Touchless sensor wired to Input 1 on a Turbine station:
Configuration on IC-Edge
To configure the Input select Edge Controller > System Configuration > Direct Access Keys.
Select Show/Hide Settings on the station you want to configure:
Configure the Input to Call To a directory number when activated.
More details can be found on Direct Access Key Settings.
Configuration on ICX-AlphaCom
TO configure the ...:
- Select Users & Stations
- Select the intercom station with the touchless sensor connected
- Open the DAK window
- Select the tab DAK 11-20
- On DAK 11 (=input 1) enter the directory number to call when the input is activated
Configuration of Inputs and Direct Access Keys (DAK) are done in AlphaPro.
Detailed information is found under DAK programming.