'''TA-10''' is a Relay Module to be used with Turbine Industrial stations [[TFIE-1]] and [[TFIE-2]], and the Turbine kits [[TKIE-1]] and [[TKIE-2]]. | '''TA-10''' is a Relay Module to be used with Turbine Industrial stations [[TFIE-1]] and [[TFIE-2]], and the Turbine kits [[TKIE-1]] and [[TKIE-2]]. | ||
[[File:1008140100.PNG|thumb|350px|The TA-10 Relay Module]] | [[File:1008140100.PNG|thumb|350px|The TA-10 Relay Module]] |
Revision as of 14:16, 10 May 2022
TA-10 is a Relay Module to be used with Turbine Industrial stations TFIE-1 and TFIE-2, and the Turbine kits TKIE-1 and TKIE-2.
Highlights
- Designed for use with Turbine Industrial stations TFIE-x, and the Turbine kits TKIE-x
- Fits inside the TFIE Industrial stations (Requires a TA-29 bracket)
- Dual high-power relays (DPDT)
- Up to 400VAC /48 VDC per relay
- Up to 8A current per relay
- Heavy-duty spring-loaded terminals with spare grounding terminals
- Powered by Turbine Industrial stations (TFIE-x) or Turbine Extended Kit (TKIE-x)
Connection
- Use the cable that comes with the TA-10, and connect one end to the Turbine Extended Board (Connector J2), and the other end to the TA-10 board as indicated in the drawing below
Configuration
AlphaCom Mode:
- Use the AlphaPro tool, and go to Exchange & System > RCO
- The two relays must be mapped in the RCO table as pin 9 and pin 10
- See RCO - Remote Control Output for more details
SIP or Pulse mode:
- Log on to the web interface of the station
- Select SIP Configuration > Relay Settings, select Relay 3 or Relay 4, and configure which event should operate the relay
- See Relay Settings for more details
Dimensions
- Dimensions (WxHxD): 100 x 50 x 40 mm
- Weight: 0.1 kg