This article shows possible solutions for redundancy with the ICX-AlphaCom server.

ICX-AlphaCom redundancy

For redundancy between ICX-AlphaCom servers, see Redundant Servers - ICX-AlphaCom.

  • High availability and fault tolerant solution maximizing uptime during
    • System level failures
    • Environment-level failures (power outage, fire, earthquake, etc.)
    • Planned outage for system maintenance and upgrades
  • Maximum downtime at switch-over (552 stations) is 35 seconds
Redundant ICX-AlphaCom system


Power Supply redundancy

The ICX-AlphaCom normally has one power supply, and it only supports one power input. Using third party products it is possible to Increase durability by adding a solution for redundant power.

Such a full redundant system might look like this:

Principal sketch for redundancy system


An example Power Supply configuration with optional TKIS-2 to provide Power Supply and ICX-500 monitoring:

Redundant Power Supply solution using Phoenix Contact products


RCO or RCI

Any physical inputs and/or outputs needs to communicate with the server via an IP device such as the TKIS-2 or an IP-LCM. These devices, as any other IP device in a redundant system must register and communicate with the operational IP address, and thus always be online with the active server.

Serial Port

The ICX-AlphaCom does not have a serial port and must use an Ethernet-to-serial converter. Since the ICX-AlphaCom redundancy system is using a singular IP address as the operational IP address the solution is to have the converter pointed at the operational IP address, and will work fine, independent on which server is the active one.

Monitoring

Monitoring the redundancy and logging is explained in this article: IPHA - Monitoring server status

The server redundancy, and/or the power redundancy can be monitored and presented live on a PC monitor using VS-Operator. See article Monitoring redundancy in VS Operator for more details.