Actions

Difference between revisions of "ECP-AA1 Connections"

From Zenitel Wiki

 
Line 62: Line 62:
  
 
*Connect the CCTV trigger input between pins 6 and 8 on the I/O connector.
 
*Connect the CCTV trigger input between pins 6 and 8 on the I/O connector.
 +
 +
==Related==
 +
[[Turbine Compact series board connectors]]
  
 
[[Category: Turbine Connections]]
 
[[Category: Turbine Connections]]

Latest revision as of 11:10, 23 June 2023

AEIPS.png

The ECP-AA1 has 2 connectors located at the bottom of the unit.

Power

The ECP-AA1 is powered through the Ethernet connector via Power over Ethernet (PoE).

The Ethernet connector is located at the bottom of the unit:

ECP-AA1 Bottom view


Ethernet connector

Type: M12, D-coded, Female, 4-pin

ECP-AA1 Connector1.png
1 TD+
2 RD+
3 TD-
4 RD-


I/O connector

Type: M12, A-coded, Fermale, 8-pin

ECP-AA1 Connector2.png
1 +5V DC
2 GND
3 I/O 1
4 I/O 2
5 I/O 3
6 Relay - common
7 Relay - NC
8 relay - NO

Connection to Emergency Break

The emergency brake provides a clean contact to the ECP-AA1. Its purpose is so that an emergency call is made as soon as the emergency brake handle is operated.

Procedure

  • Connect the clean contact between pins 2 and 3 on the I/O connector.

Connection to CCTV System

The ECP-AA1 provides a clean contact to the CCTV system. Its purpose is to send a trigger to the CCTV system when a call is made from the ECP-AA1.

Procedure

  • Connect the CCTV trigger input between pins 6 and 8 on the I/O connector.

Related

Turbine Compact series board connectors