Situation: Some gates are not equipped with door stations, but the operator want to use the same Door Opening procedure to open the door. When the operator gets a signal that there is someone at the door he should dial a dummy number, then press digit 6 to operate a relay output (i.e. a RCO).
For this function the two-step event trigger, feature 105, can be used. In AlphaPro, Directory & Features, create a directory number, feature 105, for each door. Directory number 9545 is included by default. In Exchange & System -> Events, create a new event with the following parameters:
| Event Owner: | The operator station or an UDP group |
| Event type: | 25 – Event Trigger w/User Parameter |
| Subevent: | 6 |
| When change to:: | ON |
| When related to: | Directory number: 9545 |
| Action: | RCO 4 ON 20 |
| $DISCON_ST L%1.dir U2 |