The user interface can be altered by changing parameter 2 of the recal directory number.
 +
Parameter 2 = 544.
  
 
===Hardware and software requiements===
 
===Hardware and software requiements===

Revision as of 14:11, 31 August 2010

The Recall function let you record a message from a station, and then dispatch the recorded message as a Group Call. The function is used to prevent feedback problems when making Group Calls. The recorded message is a temporary message, which is discarded when the Group Call is finished.

Directory numbers

Creating a new Recall number 9089 for group 6

Default directory numbers for "recall" broadcast:

  • 9084: Recall to group 1 (all)
  • 9085-9088: Recall to groups 2 - 5

More recall numbers can be added from AlphaPro. In the Directory & Features window, select Insert and select Feature 113 and ID = group number. Enter any free directory number and an appropriate display text.

User interface

To initiate a group call using the recall function:

  1. Dial the recall number (e.g. 9084)
  2. Press M-key, record message
  3. Release M-key, listen to the recording
  4. Press 8 to dispatch the message, M to do a new recording, 7 to hear again, or C to cancel

Using the recall function from a telephone:

  1. Dial the recall number (e.g. 9084)
  2. Press the *-button, record message
  3. Press the #-button to stop the recording and listen to the message
  4. Press 8 to dispatch the message, * to do a new recording, 7 to hear again, or C to cancel


The user interface can be altered by changing parameter 2 of the recal directory number. Parameter 2 = 544.

Hardware and software requiements

Hardware: The recall function can be used on all AMC-IP hardware versions (red or black PCB).

Software: Recall is available from AMC software version 11