Actions

IP Video Door Station - 1401110100

From Zenitel Wiki

Revision as of 11:32, 5 November 2014 by Roarl (talk) (Axis Factory Reset)
IP Video Station, item 1401110100

The STENTOFON Vandal Resistant IP Video Station (item 1401110100) is tough, durable and resilient, and designed for use in the harshest of environments. The station is typically used as a communication, information or emergency point and connects directly to the IP network making it easy to deploy – anywhere and at any distance. Designed for CCoIP® the station offers a set of critical communication features such as integrated firewall, group call, call priority and over-ride, to name just a few. This enables you to deliver instant, efficient and secure voice, video and data services in an IP environment.

Configuration

CCoIP Station

The station must be given an IP address, either static or one provided by a DHCP server. In addition the IP address of the AlphaCom and the directory number must be set. This is all done in the inbuilt webserver.

For more details, please see: IP Station IP and Server configuration


Camera

Connect to the camera using a webbrowser on default IP address 169.254.1.101.

In the menu that appears, click System Settings, and you will be asked to login:

Username: admin
Password: 1234

Set to factory default:

CP-Cam Factory Reset

This should be carried out only by experienced technicians. The customer is liable for damages caused by improper opening of the housing.

If the entered IP address is unknown, it is possible to reset the address to 169.254.1.101 using the DIP switch. To proceed, the unit must be opened.

Note: A change of the IP address is made via the web interface of the CP-CAM.

The procedure is as follows:

1. Open the CP-CAM so the two DIP switches are accessible ( see picture ).
2. Note the switch position and then turn both switches to „OFF“.
3. Connect PC with the IP number range 169.254.1.xxx and set the desired IP address in the web interface.
4. Turn switch positions back to original positions.
5. Close housing properly.
CP-CAM.PNG


Setup with STENTOFON Video Display Station

To configure the STENTOFON Video Display Station please see: IP Desktop Station with Video Display - 1408001635

This chapter describes the steps for configuring the CP-Cam:

From the Main Menu select System Settings > Network

1. Under section IP-SETUP, set IP-SETUP Type to Manual
IP-VideoDoorStation1.png


2. Enter a static IP adresss, Netmask, Gateway and DNS
3. Under section System, set Authentication required for Picture/Video to No
IP-VideoDoorStation2.png


4. Click Save Changes at the bottom of the page



From the Main Menu select System Settings > Camera

1. Under section Settings, set Mode to Custom
2. Set Res X to 320
3. Set Res Y to 240
IP-VideoDoorStation3.png


4. Under section Settings, set Frames per Second (Sensor) to 15
IP-VideoDoorStation4.png


Setup with 3rd party Video devices

SNOM IP Phones

The video image of the IP Video Door Station can be displayed on a Snom IP phone display. Following possibilities can be realized:

  • Manual video image. The video image of the IP Video Door Station can be activated and ended by key press.
  • Pop up video image. The video image of IP Video Door Station is shown automatically on an incoming call and end automatically when the communication is finished.


Conditions for displaying a video image by an incoming call:

  • Compatible Snom phone (models 820, 821, 760)
  • Registration on an AlphaCom, PULSE server or SIP-server.
  • Snom firmware must be version 8.7.4.5t.

AlphaCom configuration

The Snom phone must be configured as a SIP User in AlphaPro, Users & Stations. See article SIP phone as station for details.


Firmware update of Snom phone

The firmware of the Snom phone must be uploaded using a TFTP server. Upgrade procedure:

  • Download the software 8.7.4.5t from the AlphaWiki download site
  • Unzip the file. Remember in which folder you stored the file
  • Start a TFTP server, and browse to the folder which contains the file
  • In the Snom webinterface, select Software Update and enter address tftp://[TFTPServer]/[file name], where [TFTPServer] = IP address of PC running the TFTP server and [file name] is the name of the downloaded .bin file. Example: tftp://10.5.101.129/snom821-8.7.4.5t-SIP-r.bin.
  • Select Load, and watch the progress on the display of the Snom phone
Starting the software upgrade process


Network and SIP account in Snom phone

Factory default of the phone is done from the phones keyboard by pressing:

  • The button Menu
  • 5 - Maintenance
  • 4 - Reset Values
  • Enter default password 0000. The phone will restart.

Follow the display setup wizard to set:

  • Language
  • Time Zone
  • Tone scheme
  • SIP Account = Directory number in AlphaCom
  • Registrar = IP address of AlphaCom
  • Select DHCP or enter IP settings of phone

The phone must be rebooted after this.

SIP account settings can be changed in Identity 1 in web access. IP settings are changed in Advanced -> Network.

Codec settings

Codec must be changed to G.711u-law (pcmu) and the internal "telphone event".

In Identity 1 -> RTP, set the codec to: "pcmu,telephone-event", remove all other codecs:

Set the codec to: "pcmu,telephone-event"


Pop up video image

The screen display in the XML-Mini-Browser of Snom IP phones can be started and ended automatically. The following settings are necessary.

Configuration in Snom Phone

Firmware version 8.7.4.5t-SIP-r for the Snom phones 820, 821, 760 is required to get video pop up.

The IP Video Door Station(s) must be defined in the Directory of the Snom phone.

In the web interface of the phone, select Directory in the menu, and enter the following parameters:

  • Number: The directory number of the IP Video Door Station, as entered in AlphaPro, Users & Stations.
  • Title: Enter any text
  • Action URL: http://<IP adress of the camera>/snoma.cgi. For example http://10.5.101.97/snoma.cgi
  • Nickname: Enter any text


Configure the IP Video Door station in the Directory list of the Snom phone



Set "Call Waiting Indication" to "Off":

Set "Call Waiting Indication" to "Off"



Set SIP port to 5060:

Set SIP port to 5060




Disable "Filter packets from Registrar":

Disable "Filter packets from Registrar"



Configuration of the camera

In the camera the authentication for the image/video display has to be deactivated. Log on to the camera (default username: admin, password: 1234). Under System Settings->Network->System, change the "Authentication required for Picture/Video" to "No".


Select System Settings, then Network.



Switch off the authentication.



Set the resolution to match the video display of the Snom phone, 320 x 240 pixels:

Set resolution to QVGA 320 x 240.


Operating the Door Opening relay

During conversation with the IP Video Door Station the integrated relay of the door station can be operated by pressing digit 6 on the Snom phone. The Snom phone uses DTMF by RFC2833 by default, which is supported by AlphaCom, so no settings are required in the phone.

In AlphaCom the relay must be mapped to a logical RCO, and an "Door Opening" event created to trigger this RCO.

To map a logical RCO to the relay of the IP Station, select Exchange & System -> RCO. Pick a free RCO, select Change and set the RCO Type = Station, enter the physical number of the IP Station, and set pin number = 1. In the example below the relay of IP Video Door station 48 (directory number 148) is mapped to RCO 11.

Logical RCO 11 is mapped to the relay of station 48



Create a "Door Opening" event with the IP Video Door Station as the event owner. Select Exchange & System -> Events, and Insert a new event with the following properties:

During conversation with the door station (148), pressing digit 6 will trigger the relay (RCO 11)


For connection details, see article: IP Station Board Connections and Indications



Manual video image (Optional)

The video image of the IP Video Door Station in the Snom IP phones can be started and ended manually by pressing a function key. With this feature the video image can be displayed without setting up a conversation.

Configuration of the Snom phone

In the web interface of the phone, select Function Keys in the menu, and enter the following parameters:

  • Context: Active
  • Type: Action URL
  • Number: http://<IP adress of the camera>/snoma.cgi. For example http://10.5.101.97/snoma.cgi
  • Short text: Enter any text


Pressing function key 1 will start the video image from camera 10.5.101.97


How to use

  • Start video image: The video image is started by pressing the programmed key.
  • End video image: The video image is ended by pressing the "X-key".


Authentication

If the access of the camera is to be password protected, the following adjustments are necessary.

Configuration of the Snom phone

In the web interface of the phone, select Function Keys in the menu, and enter the following parameters:

  • Context: Active
  • Type: Action URL
  • Number: http://<User name>:<Password>@<IP adress of the camera>/snoma.cgi. If for example username is "viewer" and the password is "1234", enter http://viewer:1234@10.5.101.97/snoma.cgi
  • Short text: Enter any text


Configuration of the camera

In the camera the authentication for the image/video display has to be activated. Under System Settings->Network->System, change the "Authentication required for Picture/Video" to "Yes".

Milestone

It is assumed that a Milestone XProtect system is already installed and up and running. The latest Milestone XProtect Professional and Smart client can be downloaded from Milestonesys.com.

The version used in the examples that follows is XprotectPro V8.1a

Open the XProtect Professional Management Application by double clicking the desktop icon. Expand the mennu tree strcture and right click Hardware Devices. Select Add New Hardware Device

Milestone4.PNG



Choose Manual as the hardware detection method.

Milestone5.PNG



  • 1 Enable Use
  • 2 Type in the IP address of the camera in the Address field
  • 3 Select username admin from the dropdown box under User Name
  • 4 Enter the default IP Video Door Station camera password: 1234 in the Password field
  • 5 In the Hardware Driver dropdown box, scroll down and select Universal Driver
  • 6 Repeat for 1-5 the next camera(s)
  • 7 Click Next, followed by Finish in the next window.
Milestone6.PNG



After adding the new camera(s) to the device list, they should appear in the tree structure under Cameras and Storage Information. Right click the IP Video Station camera and select Properties

Milestone3.PNG



If the image in the preview window is visible, no more actions are required.

If there is no image shown from the camera, click on the Camera Settings... button.

Milestone2.PNG



In the Video Properties set:

  • 1 Codec: JPEG
  • 2 Streaming mode: HTTP
  • 3 Delivery mode: Multipart stream
  • 4 Retrieval mode: Streaming
  • 5 Connection URI: http://<camera IP address>/mjpg/video.mjpg
  • 6 Click Preview Image to verify that the image is shown, followed by clicking OK.
Milestone1.PNG