IP-LCM Configuration (AlphaCom mode)
From Zenitel Wiki
This article describes how to configure the inputs and ooutputs of the IP-LCM Module when used with an AlphaCom server.
The IP-LCM requires an IP Station License in order to register to the AlphaCom server.
Inputs
The IP-LCM module has in total 14 inputs:
- 6 inputs on the The TKIS-2 module itself
- 8 inputs on the IP-LCM board
- The six inputs on the TKIS-2 module are triggered by connecting the Input to GND.
- Depending on switch settings the eight inputs on the IP-LCM board are triggerd either by a close contact (default), or by a DC voltage signal. See IP-LCM Connections for details.
- The IP-LCM is configured in the same way as other Turbine devices, see Turbine configuration
- The 8 inputs of the IP-LCM module are triggering event 30, DAK/Input 18-25. See RCI configuration
- The 8 relays must be mapped to RCO pins 17-24, see RCO - Remote Control Output