Touchless sensor, item 2390020100

The Touchless sensor (item 2390020100) is an IR-sensor that connects to Turbine Compact stations and is used to activate calls with gesture recognition instead of pressing the call button.

Highlights

  • Input Voltage: 5V
  • Available contacts: Normally Open & Normally Closed
  • Sensor active time: 0,5 secs
  • Operating distance: 15cm
  • IP66

Connections

Connections are made to the switch using the supplied 5 pin plug.
Correct orientation of the plug is ensured by the connector locating guides.

Color code

  • Red - +5 Volt supply
  • Brown - 0 Volt supply
  • Green - Normally Closed
  • Blue - Common
  • Purple - Normally Open

Typical Application

Touchless sensor - general wiring


Use Case Examples

Touchless sensor wired to Input 1 on a Turbine station:

Touchless sensor - wiring example


Configuration on IC-Edge

To configure the Input select Edge Controller > System Configuration > Direct Access Keys.
Select Show/Hide Settings on the station you want to configure:

Input 1 configured to call number 13 when triggered


Configure the Input to Call To a directory number when activated.

More details can be found on Direct Access Key Settings.

Configuration on ICX-AlphaCom

TO configure the input to call a preconfigured number:

  1. Select Users & Stations
  2. Select the intercom station with the touchless sensor connected
  3. Open the DAK window
  4. Select the tab DAK 11-20
  5. On DAK 11 (= input 1) enter the directory number to call when the input is activated
Input 1 configured to call number 13 when triggered



More information is found under DAK programming.