MRBD - Relay Board

From Zenitel Wiki

Revision as of 12:47, 21 January 2015 by Asle (talk) (Features)
The MRBD board

The MRBD relay board has six relays, which are controlled by RCO's from the exchange or from a RIO unit. The MRBD must be powered by +24 VDC. The AlphaCom XE7 and XE20 comes with a 24VDC outlet for such purpose, but in the AlphaCom XE26 a Power Distribution Board PDB is required.

In the AlphaCom exchange it is recommended that all the RCOs be connected to the same ASLT board(s) in order to simplify cabling.

The MRBD board is supplied in an installation box that can be fastened onto the mounting rail on the connection field of the AlphaCom exchange, or mounted on the wall in any suitable position.

Features

  • Equipped with 6 relays, each with double pole, double throw (DPDT) contacts.
  • Max carrying current: 1.25A, 125VDC/AC.
  • Max switching current at 125VAC is 0,5A (Approx. 60W).
  • Powered by +24 VDC
  • Connector for 6 RCOs + 2 GND reference signals
  • Connects to the AlphaCom Subscriber Connection Board through a 1:1 cable
  • Fastens onto mounting rail in AlphaCom exchange

Technical Specifications

Text Value
Order Number 1009970200
Input Voltage:

Maximum Current:
Current through relay contact:

+24 VDC

60 mA (all relays active simultaneously)
1A

Relays 6 relays each with 2 changeover contacts
RCOs<br\><br\><br\> Active high or low (switch setting on the board)<br\>High = AlphaCom<br\>Low = TouchLine system or Turbine station
Recommended room temperature<br\>(non-condensing) 0'C to + 35'C<br\>+32'F to + 95' F
Humidity Range: 10% - 90% RH
Dimensions: 100 mm x 100 mm<br\>3.9" x3.9"
Connector Types: Spring terminals, AMP MTA 100 connector

Connectors and Switches

Connectors and switches on MRBD board


The jumpers S1-S6 determine if the RCO should be activated by a high or low level. High level is used in AlphaCom system, while low level was used in the previous TouchLine generation of intercom system.

Connections

AlphaCom XE7

In the XE7 the cable is connected to the 8-pin pinheader labeled RCO 1-6 or RCO 7-12.

  • An ASLT board in board position 1 is required to operate RCO 1 - 6.
  • An ASLT board in board position 2 is required to operate RCO 7 - 12.
Connection of MRBD in an AlphaCom XE7


AlphaCom XE20/26

Connection of MRBD in an AlphaCom XE20



In an AlphaCom XE26 the 24VDC power is provided by the Power Distribution Board PDB.