Situation

Some gates are not equipped with door stations, but the operator should use the same Door opening procedure to open the door. When the operator gets a signal that there is someone at the door he should dial a dummy number, then press digit 6 to operate a relay output (i.e. a RCO).

Solution

In the example below any station can dial 9545 + 6 to trigger RCO 4 for 2 seconds, and disconnect with success-tone.

Use the two-step event trigger, feature 105. In AlphaPro, Directory & Features, create a directory number, feature 105, for each door. Directory number 9545 is included by default.

In Exchange & System -> Events, create a new event:

Event Handler configuration
Event Owner: The operator station or an UDP group
Event type: 25 – Event Trigger w/User Parameter
Subevent: 6
When change to:: ON
When related to: Directory number: 9545
Action: RCO 4 ON 20
  $DISCON_ST L%1.dir U2



Explanation

  • Subevent 6: digit 6
  • When Change to ON: When the digit is pressed (not released)
  • RCO 6 ON 20: Pulse RCO 6 for 2,0 seconds
  • $DISCON_ST L%1.dir U2: Disconnect the station with successtone