Actions

Recall

From Zenitel Wiki

Revision as of 13:59, 31 August 2010 by Asle (talk)

The Recall function let you record a message from a station, and then dispatch the recorded message as a Group Call. The function is used to prevent feedback problems when making Group Calls. The recorded message is a temporary message, which is discarded when the Group Call is finished.

Directory numbers

Creating a new Recall number 9089 for group 6

Default directory numbers for "recall" broadcast:

  • 9084: Recall to group 1 (all)
  • 9085-9088: Recall to groups 2 - 5

More recall numbers can be added from AlphaPro. In the Directory & Features window, select Insert and select Feature 113 and ID = group number. Enter any free directory number and an appropriate display text.

User interface

To initiate a group call using the recall function:

  1. Dial the recall number (e.g. 9084)
  2. Press M-key, record message
  3. Release M-key, listen to the recording
  4. Press 8 to dispatch the message, M to do a new recording, 7 to hear again, or C to cancel


Hardware and software requiements

Hardware: The recall function can be used on all AMC-IP hardware versions (red or black PCB).

Software: Recall is available from AMC software version 11

License: Recall requires an Audio Messaging license.