IP Video Station, item 1401110200

Camera Type: Axis

The STENTOFON Vandal Resistant IP Video Station (item 1401110200) is tough, durable and resilient, and designed for use in the harshest of environments. The station is typically used as a communication, information or emergency point and connects directly to the IP network making it easy to deploy – anywhere and at any distance. Designed for CCoIP® the station offers a set of critical communication features such as integrated firewall, group call, call priority and over-ride, to name just a few. This enables you to deliver instant, efficient and secure voice, video and data services in an IP environment.

Installation

See article: IP Station Installation

Station Board Connectors and LED Indications

See article: IP Station Board Connections and Indications

IP Station Configuration

See article: IP Station Configuration

Reset to factory settings

See article: IP Station Restore Factory Defaults

Software Upgrade

See article: IP Station Software upgrade

Dimensions

See article: IP Stations Dimensions and Mounting Instructions

Camera configuration

Connect to the camera using a webbrowser on default IP address 169.254.1.101.

In the menu that appears, click System Settings, and you will be asked to login:

Username: admin
Password: 1234

Axis camera configuration


Compability

This table shows the camera specific settings that must be set depending on the receiver

Receiving unit Resolution Frame Rate Compression Other2 Comments
IP Video Desktop 320x240 Unlimited 30 xx yy
Cisco xxx xx xx xx xx yy
SNOM IP Phone xx xx xx xx yy
Grandstream xxx xx xx xx xx yy
PhonerLite SIP Client 320x240 Unlimited 30 xx yy
DIVUS Videophone 320x240 Unlimited 30 xx yy

These units have been tested and found to be not supported:

  • BRIA (CounterPath) SIP client
  • CPCAM viewer

Axis Factory Reset

To restore the factory settings, proceed as follows:

1. Disconnect the camera from the power supply and ethernet.
2. Remove the four screws securing the rear cover and remove it.
3. Keep the Control button pressed while you restore the power supply.
4. Hold down the button for about 15 seconds until the status LED is yellow flashing.
5. Release the Control Button. The process is complete when the status LEDs light up green.
Axis.PNG


If no DHCP server is active on your network the new default IP is 192.168.0.90.
The new default user is root with password pass