Restore to Factory Default for IP Stations without Display and Key
- IP Speaker - 1401002100/1401002500
- IP Heavy Duty - 1008072200
- IP Substation Kit - 1008090200
The procedure can be used on the IP Substation Kit - 1008090200 an on the IP Master Station Kit - 1008093000.
The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP.
- Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.
- Press the button, and power up the substation
- Keep the button pressed. Release the call button after exactly 2 blinks of the LED
- Let the LED blink for exactly 2 (Static IP) or 4 times (DHCP), then press the button again
- Keep the button pressed until it confirms successful factory reset by 2 (Static IP) or 4 (DHCP) fast blinks of the LED