VS-OPC Classic for AlphaCom - Release Notes
From Zenitel Wiki
Release State: Released
Release Version: 6.0.3.1
Installation Package: VS-OPC Classic for AlphaCom_Setup_V6.0.3.1.msi
Contents
- 1 VS-OPC Classic for AlphaCom 6.x.x.x
- 1.1 Important Note about Upgrading from version 5.x.x.x.
- 1.2 VS-OPC Classic for AlphaCom 6.0.3.1
- 1.2.1 Upgrades
- 1.2.2 Errors corrected
- 1.2.2.1 MTN-1180: OPC: hanging OPC server process
- 1.2.2.2 MTN-1183: OPC client cannot connect to OPC server after server restart
- 1.2.2.3 MTN-1321: Relay on Turbine not operating from OPC on 12.3.3.2
- 1.2.2.4 MTN-1322: Turbine extended not supported in OPC server
- 1.2.2.5 MTN-1356: The station.releatedto item does not show any info after call transfer
- 2 AlphaCom OPC Server 5.x.x.x
VS-OPC Classic for AlphaCom 6.x.x.x
Important Note about Upgrading from version 5.x.x.x.
The AlphaCom OPC server has now been renamed to VS-OPC Classic for AlphaCom. By default it is now installed in C:\Program Files (x86)\Vingtor Stentofon\VS-OPC Classic for AlphaCom and the Start menu location is Start --> Vingtor Stentofon. This is where the shortcut to OPC Configurator for AlphaCom can be found. It is therefore important to uninstall an AlphaCom OPC server with a version number earlier than 6.x.x.x, before installing this new software.
It is also required to register the server. In the installation directory right-click RegServer.exe and select Run as administrator.
VS-OPC Classic for AlphaCom 6.0.3.1
Upgrades
The OPC server is now based on .NET 4.6.2
Errors corrected
MTN-1180: OPC: hanging OPC server process
In some installations the OPC server would hang or crash. This was solved by upgrading to .NET 4.6.2 and upgrading to the latest Advosol components.
MTN-1183: OPC client cannot connect to OPC server after server restart
When the server computer running the OPC server is restarted (power failure for instance), the OPC client cannot automatically reconnect to the OPC server.This was solved by upgrading to .NET 4.6.2 and upgrading to the latest Advosol components.
MTN-1321: Relay on Turbine not operating from OPC on 12.3.3.2
The mapping of outputs has been changed on AMC-IP software 12.3.3.2. The OPC server is now independent of this mapping and will work with all AMC-IP software versions.
MTN-1322: Turbine extended not supported in OPC server
Turbine Extended has more outputs available than Turbine. These outputs are now also accessible from the OPC server
MTN-1356: The station.releatedto item does not show any info after call transfer
After a call transfer, the station.relatedto now shows the correct information
MTN-1173: In the OPC configurator About tab there is a link to download OPC core components. This link is no longer valid.
The link now connets to a page from where download of OPC core components is possible.
AlphaCom OPC Server 5.x.x.x
For the release notes of AlphaCom OPC Server 5.x.x.x please go to OPC Server - Release Notes