I/O Settings (Edge)
From Zenitel Wiki
The Turbine range of stations have configurable I/O's, i.e. you can choose if an I/O should be used as an Input or as an Output. By default all I/O's are set as Inputs.
- When configured to be an Input, the input actions are configured from Direct Access Key Settings.
- When configured to be an Output, the output operation is configured from the Edge Controller in an Edge system, but locally in the station when used in SIP mode.
By default an input is triggered by a closing contact (referred to as "NO - Normally Open"). The input can be configured as "Input NC" (NC - Normally Closed) instead. (Requires firmware 8.1.3.0 or later).
Enable Advanced Configuration mode, and select Edge Configuration > I/O from the menu
- Select either Input or Output options from the drop-down box for I/O Pins 1 to 6.
Use Inputs As Key Matrix
If there is a need for more than the 6 inputs available, it is possible to use the Use Inputs As Key Matrix and combine inputs as in a diode matrix, and in this way create more DAKs. By for example using 3 inputs it is possible to get 7 DAKs.
The different options are:
- 2 Inputs (input 1-2, DAK 1-3)
Input 2 | Input 1 | DAK key triggered |
0 | 1 | DAK1 |
1 | 0 | DAK2 |
1 | 1 | DAK3 |
0 | 0 | Last DAK released |
- 3 Inputs (input 1-3, DAK 1-7):
Input 3 | Input 2 | Input 1 | DAK key triggered |
0 | 0 | 1 | DAK1 |
0 | 1 | 0 | DAK2 |
0 | 1 | 1 | DAK3 |
1 | 0 | 0 | DAK4 |
1 | 0 | 1 | DAK5 |
1 | 1 | 0 | DAK6 |
1 | 1 | 1 | DAK7 |
0 | 0 | 0 | Last DAK released |
- 4 Inputs (input 1-4, DAK 1-15):
Input 4 | Input 3 | Input 2 | Input 1 | DAK key triggered |
0 | 0 | 0 | 1 | DAK1 |
0 | 0 | 1 | 0 | DAK2 |
0 | 0 | 1 | 1 | DAK3 |
0 | 1 | 0 | 0 | DAK4 |
0 | 1 | 0 | 1 | DAK5 |
0 | 1 | 1 | 0 | DAK6 |
0 | 1 | 1 | 1 | DAK7 |
1 | 0 | 0 | 0 | DAK8 |
1 | 0 | 0 | 1 | DAK9 |
1 | 0 | 1 | 0 | DAK10 |
1 | 0 | 1 | 1 | DAK11 |
1 | 1 | 0 | 0 | DAK12 |
1 | 1 | 0 | 1 | DAK13 |
1 | 1 | 1 | 0 | DAK14 |
1 | 1 | 1 | 1 | DAK15 |
0 | 0 | 0 | 0 | Last DAK released |
The DAK actions are configured from Direct Access Key Settings.