ICX-AlphaCom connection (Zenitel Connect Pro)
From Zenitel Wiki
Introduction
Zenitel Connect Pro (ZCP) can be linked to an ICX-AlphaCom system via a trunk.
There are two ways to call from ZCP to ICX-AlphaCom:
- Prefix: Dial the Prefix + the intercom extension in ICX-AlphaCom
- Integrated number plan: Simply dial the intercom extension without any prefix
Contents
Zenitel Connect Pro configuration
Adding the Trunk and defining the Prefix
Go to Devices and Connections > External Communication, select Trunk Type ICX-AlphaCom and click the to add a new trunk.
- Prefix: The digit(s) to dial to access the trunk
- Name: Any descriptive text
- Peer Address: The IP address of the ICX-AlphaCom
- Call Service: Call Service for an incoming call.
- Status: Reachable or Unreachable. Tells if the connection is up or down.
ICX-AlphaCom trunk |
Example: Dial prefix "0" + intercom number to access the remote station |
Integrated Number Plan
It is possible to define outgoing number ranges. Numbers in these ranges can be dialed directly, without the need to dial a prefix. This gives a possibility to make a integrated numbering plan for all ICX-AlphaCom servers in a linked network.
To define the outgoing numbers, select a defined trunk and click on on the left.
In the Outgoing Numbers Range pane, click on to define a new range and enter the From and To directory numbers.
Here the numbers 101-109 and 3401-3499 will be routed to the ICX-AlphaCom trunk |
Integrated number plan - no need to dial prefix. |
ICX-AlphaCom configuration
Defining the SIP Trunk
For the ICX-AlphaCom (and AlphaCom XE and AlphaCom E systems) the link is setup as a normal SIP-trunk, see SIP trunk configuration. The preferred codec for this link is G.722.
Door Opening from an Operator station in the ICX-AlphaCom
When an operator station receives a call from a SIP trunk, the default behavior is that digits dialed on the operator station will be handled locally in the ICX-AlphaCom, and not transmitted out on the SIP trunk.
To be able to send DTMF signals to the Zenitel Connect Pro over the SIP trunk, one have to set the operator station in a certain mode by the data command $TRUNK_SIG. The mode can be set either:
- Manually by pressing as DAK key during the call, or
- Automatically when a call is received from the SIP trunk
In AlphaPro, Exchange & System -> Events, insert an event with the following parameters:
Option 1: Manually by pressing a DAK key:
Option 2: Automatically when receiving a call from the SIP trunk:
In this example the SIP Trunk node is 100, you need to change this according to the node number used.
Note that the data command $TRUNK_SIG requires AMC software 11.5.x.x or newer.
Call Queuing between the systems
In ICX-AlphaCom the Ringing Group feature is typically used by Door Intercoms and Help Points for Call Queuing. To include an Operator station in the ZCP in a Ringing Group in ICX-AlphaCom:
- Create a Call Queue in ZCP (e.g. number 6801).
- In the ICX-AlphaCom define this number as a SIP User related to the Trunk number used toward ZCP
- Add the Call Queue number (e.g. 6801) as member of the Ringing Group in ICX-AlphaCom
Send All + Reset (to make the SIP User register).