Situation: Some gates are not equipped with door stations, but the operator want to use the same Door Opening procedure to open the door. When the operator gets a signal that there is someone at the door he should dial a dummy number, then press digit 6 to operate a relay output (i.e. a RCO).

For this function the two-step event trigger can be used, feature 105. In AlphaPro, Directory & Features, create a directory number, feature 105, for each door. Directory number 9545 is included by default. In Exchange & System -> Events, create a new event with the following parametrs:

Event Owner: A station or an UDP group
Event type: 25 – Event Trigger w/User Parameter
Subevent: 6
When change to:: ON
When related to: Directory number: 9545