Door Opening using Dummy Number (Event Handler)
From Zenitel Wiki
Situation
Some gates are not equipped with door stations, but the operator want to use the same Door opening procedure to open the door. When the operator gets a signal that there is someone at the door he should dial a dummy number, then press digit 6 to operate a relay output (i.e. a RCO).
Solution
For this function the two-step event trigger, feature 105, can be used. In AlphaPro, Directory & Features, create a directory number, feature 105, for each door. Directory number 9545 is included by default. In Exchange & System -> Events, create a new event.
Using the example below, any station can dial 9545 + 6 to trigger RCO 4 for 2 seconds, and disconnect with success-tone:
Event Owner: | The operator station or an UDP group |
Event type: | 25 – Event Trigger w/User Parameter |
Subevent: | 6 |
When change to:: | ON |
When related to: | Directory number: 9545 |
Action: | RCO 4 ON 20 |
$DISCON_ST L%1.dir U2 |
Explanation
- Subevent 6: digit 6
- When Change to ON: When the digit is pressed (not released)
- RCO 6 ON 20: Pulse RCO 6 for 2,0 seconds
- $DISCON_ST L%1.dir U2: Disconnect the station with successtone