This article describes the setup of the GSM gateway MV-370 from PORTech Communications Inc
Contents
Configuration of the MV-370
The MV-370 unit is configured via a web interface. The default IP address is 192.168.0.100. Before accessing the web page, confirm that the IP address of the configuration PC is on the same subnet, e.g. 192.168.x.x.
- Username: voip
- Password: 1234
Network settings
Change the network settings according to the network environment.
- Network > WAN Settings > IP Type = Enable "Fixed IP"
- Network > WAN Settings > IP = IP address of the Mobile VoIP unit
- Network > WAN Settings > Mask = Network mask
- Network > WAN Settings > Gateway = IP address of the network gateway
Route settings
Routing calls from Mobile to AlphaCom
Select Route > Mobile to LAN Settings
Alternative 1 (default):
- CID = *
- URL = *
This setting will give a second Dial-Tone on incoming calls to AlphaCom. The user must then dial the intercom number. The Mobile VoIP unit will connect the call 5 seconds after having received the last digit in the intercom number.
Alternative 2:
- CID = *
- URL = 101
With this setting incoming calls will automatically be connected to station 101 in the AlphaCom.
Mobile settings
- Mobile > Settings > Mobile PIN Code: If the mobile needs to be unlocked by a pin code you must choose Enable, and enter the pin code, and confirm the pin code
- Mobile > Status: Shows that the SIM card in in place, and that the Mobil VoIP unit is registered on the GSM network.
SIP settings
In the menu SIP Settings > Service Domain, enter information for "Realm 1":
- Active = ON
- Display Name = Any text
- User Name = Access number to the gateway. This is the directory number you must dial on an intercom station to access the GSM gateway. The directory number must be programmed in the AlphaCom directory table with feature 83/<SIP node>.
- Register Name = Access number to the gateway
- Domain Server = IP address of the AlphaCom
- Proxy Server = IP address of the AlphaCom
"Status" will show Registered when the gateway is registered at the SIP Registrar server in the AlphaCom.
Enable DTMF signalling by SIP INFO method:
- SIP Settings > DTMF Setting: Enable "Send DTMF SIP Info"
Limitations
Outgoing calls from AlphaCom:
- No DTMF tones can be sent from AlphaCom to the line during conversation (Nettbank kan ikke brukes).
- Digits during conversation (e.g. door opening, M-key) not possible from the phone
Configuration of AlphaCom E
The AlphaCom E needs to be configured with a SIP registrar node. Beccause the MV-370 needs to must have license for SIP phone (not SIP Trunk!).