Actions

ENA Configuration - AlphaCom mode

From Zenitel Wiki

Revision as of 13:20, 21 March 2018 by Asle (talk | contribs) (Main Settings)

UnderConstruction.png THIS ARTICLE IS UNDER CONSTRUCTION !!!

AlphaCom icon 300px.png
AlphaCom with ENA Amplifiers

This article describes the configuration required for a Exigo Network Amplifier (ENA) to operate with an AlphaCom server. The ENA Amplifiers are configured through their web interface. The AlphaCom server is configured using the PC tool AlphaPro.

Configuration of amplifier

To make an ENA Amplifier operational there are essentially three parameters to configure:

  • AlphaCom IP address
  • Amplifier directory number
  • Amplifier IP address

Log in to the Amplifier

Access the amplifier by logging into the web interface using a standard web browser:

1. Open a web browser on your PC
2. In the browser’s address bar, type the IP address of the amplifier. The login page will be displayed.
ENA Login.PNG


3. Enter Username and Password. Default username: admin. Default password: alphaadmin

The information page will now be displayed, showing the main configuration and status.

Note icon {{{1}}}


To find the IP address of the amplifier, use the Menu Selection Knob on the front of the amplifier, and navigate to Information > Network.


Main Settings

  • Click Station Main > Main Settings to access the page for configuring station mode and IP parameters.
ENA MainSettings.PNG


Station Mode: Select the Use Alphacom radio-button.

Registration Settings:

  • AlphaCom IP-address: Enter the IP address of the AlphaCom server to which the amplifier is to be registered

The amplifier has up to three directory numbers you can configure: Channel 1, Channel 2 and Audio Input. Each of these require a license.

  • CH1 Out Directory Number: Mandatory: Enter the directory number of the first loudspeaker output channel. The number must match the directory number defined in the AlphaCom server
  • CH2 Out Directory Number: Optional: If the second loudspeaker channel should be addressed separately, the second channel must be registered to the AlphaCom using this directory number
  • Audio In Directory Number: Optional: If the Line In is to be used from the amplifier, the input must be registered to the AlphaCom using this directory number

IP Settings:

  • DHCP – Select this option if the IP station shall receive IP Settings from a DHCP server.
  • Static IP – Select this option if the IP station shall use a static IP address. Enter values for:
- IP-address
- Subnet-mask
- Gateway
- DNS Server 1 (option for network administration)
- DNS Server 2 (option for network administration)
- Hostname (option for network administration)
  • Disable Reset to Factory default settings using frontboard and I/O: If enabled, factory reset will only be possible from the web interface. This is disabled by default.
  • Read IP Address: Not in use
  • Enable RSTP: RSTP is only required when using redundant networking


Click Save followed by Apply to apply the new configuration settings.

Audio Settings

To configure audio settings select Advanced Alphacom > Audio from the menu

Turbine config 4.PNG


  • Select or set values for the parameters:
- Volume Override Level
- Microphone Sensitivity
- Automatic Volume Control
- Debug Automatic Volume Control
- Conversation Mode
- Audio profile
- Audio source
- Line Out Source

Volume Override Level: Select the Volume Override Level in the range 0 to 8 from the drop-down box. The default setting is 8. This setting determines the volume to be used in the station when receving audio and the Volume Override feature is activated, see Volume Override for more details.

Microphone Sensitivity: Select the sensitivity level in the range 0 to 7 from the drop-down box. The default setting is 5. If used as a local PA panel, a setting in the 1 to 3 range will reduce the chance of acoustic feedback (howling)

Volume Control Ch1 & Ch2: Offset Gain (default routed to Amplifier/Speaker). Valid range: -62 to +24 dB

NOTE!This feature must be used with caution as incorrect settings may severely degrade the performance of the echo-cancelling algorithm.

Automatic Volume Control: Check the box to enable automatic volume control that is adjusted according to the noise level

Debug Automatic Volume Control: Check the box to show current volume level on OLED display

Conversation Mode: For this parameter, there are five options:

Full Open Duplex: Normal mode with echo cancellation.
Robust Duplex: Option used when open duplex fails due to excessive speaker loudness, microphone overload or very high nonlinear distortions.
Half Duplex Switching: Switches speech direction depending on who speaks the loudest.
Push-To-Talk: Half-duplex communication. Initially the microphone is shut off. Push the M-button to open the microphone, and release to listen. (Only applicable to stations with M-key)
Open: Full Open Duplex without echo cancellation

Audio Profile: This parameter has the following options:

Normal
Noisy Environment
Very Noisy Environment
Advanced. Note!: Advanced options are for experienced users only! Incorrect settings may severely degrade the acoustic performance and intelligibility. Use with care!
See Turbine Audio Profiles for more details

Audio Source: This parameter has the following options:

Normal Microphone
Line In (for Turbine Extended intercoms only)

Line Out Source: Let you choose if the Speaker signal (the VoIP stream from AlphaCom) also should be played on the Line Out output, or if the Microphone signal should be routed to the Line Out output.

When used with an external amplifier (and speakers), use Speaker. When using the built-in microphone as an input to another system, use Microphone.

I/O Settings

These settings let you choose if an I/O should be used as an Input or as an Output. By default all I/O's are set as Inputs.

  • Select Advanced AlphaCom > I/O Settings from the menu
TCIS Configuration-8.PNG


  • Select either Input or Output options from the drop-down box for I/O Pins 1 to 6.

See also the article Turbine Inputs and Outputs in AlphaCom.

OLED Labels

See article OLED Labels on how to configure the display in the station models TCIS-4 and TCIS-5.

Address Book

See the article Address Book on how to configure the address book of the station models TCIS-6 and TCIV-6.

Keyboard Settings

Applies to the station models TFIE-x (Industrial station) and TFIX-x (Explosion proof station). See article TFIE Keyboard Settings for more details.

Sound Detection

The Sound Detection, also known as Voice Activity Detection (VAD) samples the audio level from the microphone located in the IP Station. If the audio level meets defined criterias an action in AlphaCom can be triggered.

Read more about Sound Detection.

Time Settings

  • Select Advanced AlphaCom > Time Settings from the menu
Turbine config 5.PNG


Time Settings: You can enable Network Time Protocol, select the time zone and set the hostname or the IP address of the NTP server.

Logging

From the web interface of the station it is possible to activate logging, which can be useful for debugging and troubleshooting purposes. See Logging - IP Stations for more information.

Configuration of the AlphaCom server

AlphaPro configuration

Define a User

The station is defined in Users & Stations window, General tab. For minimum configuration you need to enter these fields:

  • Directory Number - must match the directory number configured in the IP station itself
  • Display Text - Any free text. Used as Caller ID.
  • Station Type - Set to Substation unless the station has full keypad 0-9. If full keypad, set Master Station
  • CCoIP Station - Tick this checkbox when IP Station (and not analog station) is used
  • Reg. w/Directory Number - When checked (most common setting) the station will register to the AlphaCom server by its Directory Number. When unchecked the station will register by its MAC address. With this option you need to enter the MAC address of the station in the MAC Address field.
Users & Stations window


Note icon {{{1}}}


In hybrid exchanges (AlphaCom XE7, XE20 and XE26), where there is a mix of analog and IP stations, you should avoid using physical numbers for IP Stations that later might be used for analog intercom stations.

Configure the Call Button(s)

  • Go to the Users & Stations window, and select the station from the list box.
  • Press the button DAK (Direct Access Key)
  • Enter the number to call on line 1 (and on line 2 if the station has two call buttons)
Configuring the Call Buttons (DAK) on a Turbine station


AlphaWeb configuration

Filter settings

Log on to the web interface of the AlphaCom server, and select System Configuration > Filters.

Enable "IP Stations" on TCP port 50001 and "VoIP Audio" on UDP ports 61000-61150 on the ethernet port used for the IP stations. By default these ports are enabled on ethernet port 1.

Enable ports for IP Stations


IP Station licenses

The IP Stations require IP Station license in the AlphaCom server.