Actions

ENA Amplifier - Report faults to Display Station

From Zenitel Wiki

Revision as of 15:45, 11 April 2018 by Asle (talk | contribs)
AlphaCom icon 300px.png

Faults in the ENA Amplifier can be reported to a display station, e.g. to IP Desktop, DualDisplay or CRMV station.

In this example all ENA Amplifiers are included in UDP Group 3.

In AlphaPro, select Exchange & System > Events, and Insert a new event with the following properties:


IF %chg(1,0)
$STM %1.ref L164 U%op(70,+,%sev) '(%1.dir) %2.nam'
STOP
ENDIF
$CANM %1.ref L164 NM253 U%op(70,+,%sev)