Actions

ENA Amplifier - Report faults to Display Station

From Zenitel Wiki

Revision as of 10:31, 12 April 2018 by Asle (talk | contribs)
AlphaCom icon 300px.png

Faults in the ENA Amplifier can be reported to a display station, e.g. to IP Desktop, DualDisplay or CRMV station.

In order to have one common event for all ENA amplifiers, include the amplifiers in an UDP Group. Here UDP Group 3 is used as an example.

In AlphaPro, select Exchange & System > Events, and Insert a new event with the following properties:


Event 43 is used to report amplifer errors

Action Command:

IF %chg(1,0)
$STM %1.ref L164 U%op(70,+,%sev) '(%1.dir) %2.nam'
STOP
ENDIF
$CANM %1.ref L164 NM253 U%op(70,+,%sev)