TCIV+ Software Upgrade

From Zenitel Wiki

Revision as of 08:56, 16 August 2022 by Roarl (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
AEIS.png

This article describes how to upgrade the software of the Turbine TCIV+ series via the web interface of the station. This process is best suited for upgrading only a few stations.

The procedure described is applicable to the following devices: TCIV-2+, TCIV-3+, TCIV-5+, TCIV-6+ and TKIV+

If you want to upgrade Turbine station models TCIV or TCIS go to Turbine Software Upgrade

Note icon For mass upgrade of stations it is recommended to use the VS-IMT tool, see the article IMT - Discover & Upgrade.


Upgrade procedure

  1. Download the package and store the files in a folder on your PC.
  2. Log on to the Turbine Station web interface. Default login credentials are admin and alphaadmin. Select Station Administration > Manual Upgrade
  3. Drag and drop the software packaged in the Software Update window. Alternatively, you can click inside the Software Update window and browse for the file. The software package will be uploaded. The time it takes to upload will depend on the network connection.
  4. After the software package is uploaded to the station, the same will be used to upgrade the station
  5. When the upgrade process is finished, the station will be rebooted


Software upgrade



Dual partitions

The devices covered by this article comes with Dual Partitions, which allows for:

  • Software upgrade in IPv6 network
  • Software upgrade when device is using 802.1X authentication

The two partitions are called A and B. The information page shows which one is currently active:

Main > Information shows which of the two partitions that is currently active



When upgrading the firmware, the partition which is currently not in use will be updated. When the update is finished, the device will restart using the newly updated partition.

If for some reason the newly updated partition doesn't work properly, it is possible to roll back to the other partition:

Rollback to the other partition