Tamper switch
From Zenitel Wiki
The IP Vandal Resistant Substation with TKIE has the possibility to be fitted with a tamper switch. Making it possible to raise an alarm if the station is dismounted from the backbox.
Contents
Configuration
For a single station
In AlphaPro, create this event for the Tamper Switch, setting the substation as the event owner:
Action commands:
$STM L110 L101 U145 'TAMPER CELL 10'
- $STM - Send Text Message command
- L110 - Send from 110
- L101 - Send to 101
- U145 - Priority level 145
- TAMPER CELL 10 - Text to show in the display of the receiver (101 here)
For multiple (or all) stations
In AlphaPro, create the event below, and configure an UDP group as event owner (UDP group 8 is by default all stations):
Action commands:
$STM L%2.dir L101 U145 'TAMPER %1.nam'
Verify that I/O 3 is set as an input
The IP Substation must have I/O number 3 defined as an input (default).
Mounting
Mounting instruction on Tamper Switch for IP Vandal Resistant Substation TKIE
Step 1: Remove the two nylon nuts shown below
Step 2: Attach the supplied spacers
Step 3: Mount the tamper switch board
Step 4: Move the button GND wire from the the TKIE board to the tamper switch board
Step 5: Use the supplied wires to connect GND and Input 3 as shown below