VSF-Fortitude6 7.5 Release Notes
From Zenitel Wiki
- Previous Release - VSF-Fortitude6 7.4 Release Notes
This document provides the release notes for VSF-Fortitude6 7.5 with incremental bug fix releases. The release notes for VSF-Fortitude6 7.5 describe new features, improvements and issues fixed after VSF-Fortitude6 7.4.3.0.
Contents
- 1 Release info
- 2 VSF-FORTITUDE6 7.5.3.1
- 2.1 Improvements
- 2.2 Fixed Issues
- 2.2.1 MTN-4008 Syncing is now properly mapped for Alphacom "Noise Reduction" configuration level 0 to 7
- 2.2.2 MTN-3958 Changing VoIP port range adds 1000 ports to the start value
- 2.2.3 MTN-3910 Uploaded certificates can now be deleted
- 2.2.4 MTN-3906 Device now waits for the ONVIF subscription timer to run out before deleting subscription
- 2.2.5 MTN-3896 Factory reset audio parameters now affects only Audio Settings page
- 2.2.6 MTN-3884 Fixed sending of unnecessary DHCP requests
Release info
Name: VSF-Fortitude6
Description: VSF-Fortitude6 is a firmware for IP Desk Master -V2, IP Desk Master -V2-P, IP Flush Master -V2 and IP-CROR.
The firmware is delivered in two different files:
- vsff6-7.5.3.x - Used for standard in-field upgrades
- vsff6-prod-7.5.3.x - Used in production- and recovery upgrades.
Version: 7.5.3.1
Date: 23.05.2023
Status: General Availability
VSF-FORTITUDE6 7.5.3.1
Improvements
MTN-4004 Added support for more complex passwords
Passwords can now be 32 characters long, numbers, letters and the following special characters are supported ?!@$*,.- The password must meet the following criteria:
- Minimum length of 8 characters
- At least three out of the following four requirements must be met:
- Contains at least one digit (0-9)
- Contains at least one uppercase letter (A-Z)
- Contains at least one lowercase letter (a-z)
- Contains at least one special character
MTN-3259 Added option to make device ringlists independent of Edge Controller ringlist updates
When ‘No updates from Edge Controller’ checkbox is enabled, the ringlist is managed locally in the station. Global ringlist configuration in the Edge Controller is then ignored.
Fixed Issues
MTN-4008 Syncing is now properly mapped for Alphacom "Noise Reduction" configuration level 0 to 7
The new configuration "Moderate" was not mapped. New mapping:
- 0: ANC Disabled
- 1,2: ANC Enabled with Low Suppression
- 3,4: ANC Enabled with Moderate Suppression
- 5,6: ANC Enabled with High Suppression
- 7: ANC Enabled with Very High Suppression
MTN-3958 Changing VoIP port range adds 1000 ports to the start value
Max port number is 65535, if start value is higher than 64535, remaining ports are allocated.
MTN-3910 Uploaded certificates can now be deleted
The deletion of certificates uploaded in the device web was previously not possible. This is now fixed.
MTN-3906 Device now waits for the ONVIF subscription timer to run out before deleting subscription
Subscription timer for ONVIF messages was running out before the message timer. This is now fixed.
MTN-3896 Factory reset audio parameters now affects only Audio Settings page
Factory reset audio parameters doesn't affect VAD, Tone Test and DAVC settings, only settings which are configured on Audio Settings page.
MTN-3884 Fixed sending of unnecessary DHCP requests
Correct configuration is applied to interface and unnecessary DHCP requests will not be sent anymore.