Actions

APC - AlphaCom Program & Clock Board

From Zenitel Wiki

Revision as of 12:46, 15 August 2007 by Asle (talk)
APC Program & Clock Board
APC board, connection and adjustment

The APC board is mandatory in the AlphaCom E20 and E26 exchanges. It controls the back plane board clocking. It also supervises board temperatures and controls the speed of the fans. This board contains circuitry for 6 audio program feed channels with galvanic isolation. Easily accessible potentiometers at the front enable sensitivity control of the audio program input. The clock can be synchronized with (phase-locked to) an external clock. The board plugs into position 26 only.

Features

  • System master clock (two-phase - 16.384 Mhz) and module reset
  • Circuitry for 6 audio program feed channels
  • Can be fed by any analog source
  • Galvanic isolated input via 600 ohm transformer to avoid noise problems
  • Adjustable sensitivity (gain)
  • 6 alarm inputs
  • 2 internal alarms
  • Reset button
  • Fan control
  • Coded connector to ensure correct positioning in the module
  • Power connector (6-pin socket source) for hot plug-in cable

Technical Specification

Order Number: 100 9301 000
Operation Voltage: 5, 15, 24, V DC
Dimensions (WxHxD) <br\><br\> 10mm x 230mm x 263mm <br\> 0.39"x 8.97"x 10.26" <br\> Double Extended Europe Format
Sensitivity (adjustable) 100 mV to 1 V
Frequency range with program reed 200-15,000 Hz
Indicator: Drives module status indicator on front panel