Actions

Difference between revisions of "1-4j. RCO, Call indication (practice)"

From Zenitel Wiki

(Exercise)
 
(9 intermediate revisions by the same user not shown)
Line 2: Line 2:
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 
=== Exercise ===
 
=== Exercise ===
'''Call indication'''
+
'''Private Ringing indication'''
*When calling the Control Room a lamp (RCO 4) at the control room should be activated when the private ringing starts. (The Control Room is in “Private” mode).
+
*When calling the Main Guard in private ringing mode, a lamp controlled by the relay in the station should be activated when the private ringing starts. (The Main Guard must be set in “Private” mode by pressing the C-key for more than 2 sec.).
 
*The lamp should be turned off when the private ringing stops.
 
*The lamp should be turned off when the private ringing stops.
 +
* Use logical RCO 10 to operate the relay
 +
 +
 +
'''Call Queue indication'''
 +
*When the Main Guard receives a '''Call Request''', the same lamp should be activated to indicate that there is one or more calls in the call queue (Tip: Use event "''Priority Mail Present''").
 +
*The lamp should be turned off when there are no more calls in the queue.
  
  
'''Call indication, modified'''
 
*The customer changes his mind; the lamp should go on when the private ringing starts and stay on also during the conversation. When the conversation ends the lamp should be switched off. If the call is not answered, the relay must drop when the ringing times out. The lamp should not go on when the Control Room makes an outgoing call, only when receiving a call.
 
  
 
<br><br><br><br>
 
<br><br><br><br>
Line 15: Line 19:
  
 
===Related articles ===
 
===Related articles ===
* [[2-2a. Call indication - Event Handler (solution)]]
+
* [[1-4j. RCO, Call indication (solution)]]
  
  
 
[[Category: AlphaCom practice]]
 
[[Category: AlphaCom practice]]

Latest revision as of 16:14, 29 June 2016

System configuration


Exercise

Private Ringing indication

  • When calling the Main Guard in private ringing mode, a lamp controlled by the relay in the station should be activated when the private ringing starts. (The Main Guard must be set in “Private” mode by pressing the C-key for more than 2 sec.).
  • The lamp should be turned off when the private ringing stops.
  • Use logical RCO 10 to operate the relay


Call Queue indication

  • When the Main Guard receives a Call Request, the same lamp should be activated to indicate that there is one or more calls in the call queue (Tip: Use event "Priority Mail Present").
  • The lamp should be turned off when there are no more calls in the queue.







Related articles