System configuration


Solution

Private Ringing indication

  • When calling the Main Guard in private ringing mode, a lamp controlled by the relay in the station should be activated when the private ringing starts. (The Main Guard must be set in “Private” mode by pressing the C-key for more than 2 sec.).
  • The lamp should be turned off when the private ringing stops.
  • Use logical RCO 10 to operate the relay

The first step is to map the logical RCO 10 to the relay of station 400:

Output 1 of station 400 (physical 37) is mapped to RCO 10


The second step is to create an event that operates the RCO 10 when the right conditions are met. In Users & Stations, select the station "Main Guard" from the list box, and press the button Events. Insert a new event with the following properties:

Call button of station 107 will call station 101



Call Queue indication *When the Main Guard receives a Call Request, the same lamp should be activated to indicate that there is one or more calls in the call queue (Tip: Use event "Priority Mail Present").

  • The lamp should be turned off when there are no more calls in the queue.