All intercom stations are connected by means of pluggable screw terminals on the exchange back-plane. Line points 5 and 6 are by default used as program distribution inputs on line c-d when an ASLT board is placed in board pos. 1.
 
All intercom stations are connected by means of pluggable screw terminals on the exchange back-plane. Line points 5 and 6 are by default used as program distribution inputs on line c-d when an ASLT board is placed in board pos. 1.
 +
 +
See related article: [[Physical number 5 and 6 (AlphaCom E7)]]
 +
 
* The jumpers P5 and P6 are set to pos 2-3.
 
* The jumpers P5 and P6 are set to pos 2-3.
 
* The potmeters P5 and P6 are used to adjust the input level. Line points 5 and 6 can also be used as normal subscriber points.
 
* The potmeters P5 and P6 are used to adjust the input level. Line points 5 and 6 can also be used as normal subscriber points.

Revision as of 10:50, 4 November 2016

ASLT Subscriber Line Board

Highlights

  • Can be used with InterGuard, TouchLine and Pamex stations
  • Each board provides 6 subscriber connections
  • 6 RCO remote control outputs (software configurable activation)
  • 1 voice-switched conversation per board
  • When using handset or full duplex conference unit at both ends, the system is non-blocking within each module
  • All subscriber connections suitable for display stations
  • Line monitoring
  • Software-controlled output volume control
  • Hot plug-in/plug-out
  • Red/green/amber LED indicates system status

Additional Documentation on Zenitel.com

Installation

AlphaCom XE20/XE26

There are three different subscriber connection methods available:

  • Subscriber connection board (1009930200) with 1.5 m connection cables (1009501011) or 3.0 m connection cable.
2 pcs. of 1009930200 and 1009501011 are included with the E20 and E26 exchange packages.
Station and RCO connection to ASLT in AlphaCom XE20 and XE26


AlphaCom XE7

All intercom stations are connected by means of pluggable screw terminals on the exchange back-plane. Line points 5 and 6 are by default used as program distribution inputs on line c-d when an ASLT board is placed in board pos. 1.

See related article: Physical number 5 and 6 (AlphaCom E7)

  • The jumpers P5 and P6 are set to pos 2-3.
  • The potmeters P5 and P6 are used to adjust the input level. Line points 5 and 6 can also be used as normal subscriber points.
  • Set jumpers 5 and 6 to pos 1-2
  • In AlphaPro, select Exchange & System >Boards
  • Change the port setting from ‘Audio program feed’ to ‘Default’
  • Reset the exchange

The RCO outputs 1-6 are associated with the board in pos. 1, and RCO 7-12 with the board in pos. 2.

Station, program and RCO connection to ASLT in AlphaCom XE7


Cabling

Desktop stations are connected to the line on RJ45 wall sockets.

Compatibility

The four-wire interface provides compatibility with existing standard station range from STENTOFON with the exception of TouchLine display stations produced earlier than March 1995. These stations are no longer compatible due to reduction on the display signal output from the exchange. TouchLine display stations produced after March 1995 are labeled version 1.1 and are fully compatible with the AlphaCom exchange.