Actions

Difference between revisions of "AlphaPro 11.xx - Release Notes"

From Zenitel Wiki

(Registered Issues)
(Registered Issues)
Line 28: Line 28:
  
 
===Registered Issues===
 
===Registered Issues===
===={{Bugzilla|264}}: Not Possible to add several feature 95 and 105 with same ID.====
+
===={{Bugzilla|264}}: Not Possible to add several feature 95 and 105 with same Parameter 1.====
 
Corrected.
 
Corrected.
 
===={{Bugzilla|280}}: No audio in IP Station if packet size=30 ms.====
 
===={{Bugzilla|280}}: No audio in IP Station if packet size=30 ms.====

Revision as of 11:11, 14 June 2010

Software in production: AlphaPro 11.0.x.x
Software released date: yyyy-mm-dd
NOTE 1: AlphaPro requires Windows 2000 or XP to run. It is not yet compatible with Windows Vista/Windows7. See this article for more on running AlphaPro on Windows 7

AlphaPro 11.0.x.x (yyyy-mm-dd)

Run InstallAlphaPro.exe from the installation set. 
It is recommended that this version is not installed on top of previous installations of AlphaPro 10.xx. It is not necessary to uninstall
older version before installing this version. 
It is necessary to have administrator rights to install AlphaPro.

(BZ = Bugzilla reference number)

Functional Changes

Implemented "Defragment Action Strings Table" function

The function is available at the File menu in AlphaPro. See this article for more information.

Implemented Parameter 3 in Directory Number Table

The new Parameter 3 field is now available in the Directory & Features window.

New Directory numbers in Autoload:

Added Directory numbers related to the Audio Messaging Features

Added Feature 105 and 109 to COS 15

Errors Corrected

Unregistered Issues

Small typo in english mdf.files.

Corrected.

Allow duplicate Feature/Parameter 1 Directory numbers for Feature 111,112 and 113, and add these features to Default COS

Corrected.

Registered Issues

BZ 264: Not Possible to add several feature 95 and 105 with same Parameter 1.

Corrected.

BZ 280: No audio in IP Station if packet size=30 ms.

Corrected.

BZ 114: 627 and 628 incorrectly autoloaded.

Corrected.

BZ 188: Autoload Changes.

Corrected.

BZ 272: Assign DAK code 9541 doesn't work if the DAK is already programmed.

Corrected.

BZ 276: Cluster export of single users.

Corrected.

BZ 115: SIP Trunk not operational when 1 x Trunk and 1 x SIP station license.

Corrected.

BZ 358: Not possible to insert new feature 112 or 113 with same param1 value.

Corrected.

BZ 359: Change text from "CRM 3 and 4" to "CRM IV and V" in Station Type.

Corrected.

BZ 364: Include Dutch language Autoload database.

Corrected.

BZ 373: Easy IP station config.

Corrected.

BZ 394: Dirno 9184 and 765 is autoloaded incorrectly.

Corrected.