Actions

Difference between revisions of "Audio Messages - Turbine"

From Zenitel Wiki

(Uploading audio files)
Line 21: Line 21:
 
* Select '''Advanced AlphaCom''' > '''Audio Messages'''.
 
* Select '''Advanced AlphaCom''' > '''Audio Messages'''.
 
* '''Browse''' to the desired audio file, and press '''Upload'''. The file will now appear in the list of audio files. The web interface shows you how much space there is left of the total of 20 MB. It is possible to delete audio files from the web interface to free up space.
 
* '''Browse''' to the desired audio file, and press '''Upload'''. The file will now appear in the list of audio files. The web interface shows you how much space there is left of the total of 20 MB. It is possible to delete audio files from the web interface to free up space.
[[File:Turbine AudioMessageAC 4932.PNG|thumb|left|500px|Alarm Messages page]]
 
<br style="clear:both;" />
 
  
 
* You can now '''Choose Message''' to play, and what '''Event''' should trigger the message. There are three events:
 
* You can now '''Choose Message''' to play, and what '''Event''' should trigger the message. There are three events:
Line 30: Line 28:
  
 
* In the '''Options''' field you choose if the message should play '''One Time''', or if it should '''Repeat''' with predefined interval.
 
* In the '''Options''' field you choose if the message should play '''One Time''', or if it should '''Repeat''' with predefined interval.
 +
 +
[[File:Turbine AudioMessageAC 4932.PNG|thumb|left|500px|Alarm Messages page]]
 +
<br style="clear:both;" />
  
 
{{note|If the station is configured to play a message when "Call Setup Failed", it will not speak its own IP address when the call button is pressed when the station is offline}}
 
{{note|If the station is configured to play a message when "Call Setup Failed", it will not speak its own IP address when the call button is pressed when the station is offline}}
  
 
[[Category:Turbine Configuration]]
 
[[Category:Turbine Configuration]]

Revision as of 16:10, 16 January 2019

AlphaCom icon 300px.png

This article described how a Turbine station in AlphaCom mode can be configured to play a custom media (WAV) file when the connection to the AlphaCom server is lost.

An audio message can be played:

  • When the station goes offline
  • If the Call Button (or an input) is activated while the station is offline
  • When the station goes online

Software and hardware requirements

Preconditions

  1. Audio file for upload needs to be WAV file format, PCM 16 bit, 16 kHz and single channel (Mono)
  2. Total messages file size 20 MB
  3. A filename can have max 50 characters
  4. Any number of audio files can be uploaded, as long as the total file size is below 20 MB

Uploading audio files

  • Log into the IP Station
  • Select Advanced AlphaCom > Audio Messages.
  • Browse to the desired audio file, and press Upload. The file will now appear in the list of audio files. The web interface shows you how much space there is left of the total of 20 MB. It is possible to delete audio files from the web interface to free up space.
  • You can now Choose Message to play, and what Event should trigger the message. There are three events:
    • Station Offline: The message is played the moment the station looses connection to the AlphaCom
    • Call Setup Failed: The message is played if the Call Button (or an input) is activated while the station is offline
    • Station Online: The message is played the moment the station gets registered to the AlphaCom
  • In the Options field you choose if the message should play One Time, or if it should Repeat with predefined interval.
Alarm Messages page


Note icon If the station is configured to play a message when "Call Setup Failed", it will not speak its own IP address when the call button is pressed when the station is offline