Actions

Door Opening using Dummy Number (Event Handler)

From Zenitel Wiki

Revision as of 16:56, 14 December 2007 by Asle (talk)

Situation

Some gates are not equipped with door stations, but the operator should use the same Door opening procedure to open the door. When the operator gets a signal that there is someone at the door he should dial a dummy number, then press digit 6 to operate a relay output (i.e. a RCO).

Solution

In the example below any station can dial 9545 + 6 to trigger RCO 4 for 2 seconds, and disconnect with success-tone.

Use the two-step event trigger, feature 105. In AlphaPro, Directory & Features, create a directory number, feature 105, for each door. Directory number 9545 is included by default.

In Exchange & System -> Events, create a new event:

Event Handler configuration
Event Owner: The operator station or an UDP group
Event type: 25 – Event Trigger w/User Parameter
Subevent: 6
When change to: ON
When related to: Directory number: 9545
Action: RCO 4 ON 20
  $DISCON_ST L%1.dir U2



Explanation

  • Subevent 6: digit 6
  • When Change to ON: When the digit is pressed (not released)
  • RCO 6 ON 20: Pulse RCO 6 for 2,0 seconds
  • $DISCON_ST L%1.dir U2: Disconnect the station with successtone