Actions

Difference between revisions of "ENA Amplifier - Monitoring"

From Zenitel Wiki

 
Line 1: Line 1:
{{A}} The ENA Amplifier provides extensive monitoring capabilities.
+
{{AI}} The ENA Amplifier provides extensive monitoring capabilities.
 
<br>
 
<br>
 
== What can be supervised?==
 
== What can be supervised?==

Latest revision as of 15:02, 3 May 2021

AI.png

The ENA Amplifier provides extensive monitoring capabilities.


What can be supervised?

Error reporting

Fault and Warning icons in Amplifier display
  • Fault Relay: The Fault Relay on the back of the amplifier will trigger whenever there is an error. The relay will remain triggered as long as one or more errors are present.
  • Amplifier GUI display: Faults are indicated in the Amplifier GUI display with a red icon. Warnings are indicated with a yellow icon. Use the Menu Selecetion Knob in front of the amplifier to navigate to Service > Local Message List to view current error messages
  • Amplifier web interface: In the Faults section in the Amplifier Settings > Status menu there is a live update of current active faults. The page is automatically refreshed every 10 seconds.
  • AlphaCom System Log: Amplifier errors are reported to the AlphaCom, which will forward the error reports via the System Log. Log data can be stored in a local log file on the AMC-IP board, or sent to external log recipient via SysLog, E-Mail or SNMP trap.
  • AlphaCom Event Handler: Amplifier errors are reported by the Event Handler of the AlphaCom, event 43 - Station Fault Report. One can use the "subevent" to filter on specific fault types. The fault events can be used e.g. to generate fault messages to a display station.