Faults in the ENA Amplifier can be reported to a display station, e.g. to IP Desktop, DualDisplay or CRMV station.
+
Faults in the ENA Amplifier can be reported to a display station, e.g. to [[IP Desktop Master Station - 1008001000|IP Desktop]], [[IP Dual Display Station - 1008007000|DualDisplay]] or [[CRM V - Control Room Master|CRMV station]].
  
In this example all ENA Amplifiers are included in [[UDP group|UDP Group 3]].
+
In order to have one common event for all ENA amplifiers, include the amplifiers in a [[UDP group|UDP Group]]. Here UDP Group 3 is used as an example.
  
 
In AlphaPro, select '''Exchange & System''' > '''Events''', and '''Insert''' a new event with the following properties:
 
In AlphaPro, select '''Exchange & System''' > '''Events''', and '''Insert''' a new event with the following properties:

Revision as of 11:29, 12 April 2018

AlphaCom icon 300px.png

Faults in the ENA Amplifier can be reported to a display station, e.g. to IP Desktop, DualDisplay or CRMV station.

In order to have one common event for all ENA amplifiers, include the amplifiers in a UDP Group. Here UDP Group 3 is used as an example.

In AlphaPro, select Exchange & System > Events, and Insert a new event with the following properties:


Event ENA Errors.PNG

Action Command:

IF %chg(1,0)
$STM %1.ref L164 U%op(70,+,%sev) '(%1.dir) %2.nam'
STOP
ENDIF
$CANM %1.ref L164 NM253 U%op(70,+,%sev)