|'''Event type''': || 25 - Event trigger with User Parameter
 
|'''Event type''': || 25 - Event trigger with User Parameter
 
|-
 
|-
|'''Subevent''': || Parameter-attribute of the Event Trigger number, see below
+
|'''Subevent''': || Equal to the dialed digit (0 – 9)
 
|-
 
|-
 
|'''When change to ON''': || When a digit is pressed  
 
|'''When change to ON''': || When a digit is pressed  

Revision as of 18:37, 12 November 2007

The event type 25 is triggered by a so-called "two-step" event trigger. There are two different types, one which waits for a complete directory number to be dialled, and the other type which triggers on every digit dialled:

  • Dialling feature 95 (9535 + dir no), or
  • Dialling feature 105 (9545 + digit)


Event description - Event Trigger directory number (95)

Event Owner: The calling station
Event type: 25 - Event trigger with User Parameter
Subevent: Parameter-attribute of the Event Trigger number, see below
When change to ON: When dialing Event Trigger + succeeding dir no
When change to OFF: N/A
When related to: The succeeding dir no

Additional information

  • The parameter-attribute of the Event Trigger directory number (95/n) must match the sub-event.
  • Example: Feature 95/2 will trigger event type 25, sub-event 2
  • The user can dial more than one directory number, an Event Report type 25 is generated for each directory number dialed
  • %1 is the station were the function is dialed
  • %2 is the dialed directory number
  • If the station has mail in its queue, the %2 directory number will default to the sender of the current mail. The user can press M-key to accept the default, or dial another number. This is useful for queue handling.
  • 20 second timeout on inactivity
  • $DISCON_ST can be used for termination with desired tone

Application

Build special functions such as “dynamic grouping”

Event description - Event Trigger digits (105)

Triggered by Event Trigger feature 105 (9545 + digit) or digits pressed during conversation with a station of ’PNCI’ type:

Event Owner: The calling station
Event type: 25 - Event trigger with User Parameter
Subevent: Equal to the dialed digit (0 – 9)
When change to ON: When a digit is pressed
When change to OFF: When a digit is released
When related to: The Event Trigger or the PNCI directory number

Additional information

  • Feature parameter = ‘0’ (105/0): The pressed digit is shown in the display
  • Feature parameter = ‘1’ (105/1): The display is not updated. Display text can be customized by using $DSPL (to indicate ‘left’, ‘up’ etc)
  • Start event: Event 15 is reported ON, %1 = station, %2 = Event Trigger dir no. Corresponding OFF-event when the feature is disconnected (only related to feature 105, not when calling PNCI)
  • If sub-event is set to 255 all digits will be reported. Use %SEV to read the sub-event number (= digit 0 - 9)
  • 20 second timeout on inactivity
  • $DISCON_ST can be used for termination with desired tone

Applications

CCTV camera control, recorders, PABX, door opening