The Turbine range of stations have configurable I/O's, i.e. you can choose if an I/O should be used as an Input or as an Output. By default all I/O's are set as Inputs.

  • When configured to be an Input, the input actions are configured from Direct Access Key Settings (an input behaves like a push button).
  • When configured to be an Output, the output operation is configured from the Edge Controller in an Edge system, but locally in the station when used in SIP mode.

Select SIP Configuration > I/O from the menu

IOsettings.png


  • Select either Input or Output options from the drop-down box for I/O Pins 1 to 6.

Use Inputs As Key Matrix

If there is a need for more than the 6 inputs available, it is possible to use the Use Inputs As Key Matrix and combine inputs as in a diode matrix, and in this way create more DAKs. By for example using 3 inputs it is possible to get 7 DAKs.

The different options are:

  • 2 Inputs (input 1-2, DAK 1-3)
Input 2 Input 1 DAK key triggered
0 1 DAK1
1 0 DAK2
1 1 DAK3
0 0 Last DAK released


  • 3 Inputs (input 1-3, DAK 1-7):
Diode matrix when using 3 inputs to activate 7 DAK keys
Input 3 Input 2 Input 1 DAK key triggered
0 0 1 DAK1
0 1 0 DAK2
0 1 1 DAK3
1 0 0 DAK4
1 0 1 DAK5
1 1 0 DAK6
1 1 1 DAK7
0 0 0 Last DAK released


  • 4 Inputs (input 1-4, DAK 1-15):
Input 4 Input 3 Input 2 Input 1 DAK key triggered
0 0 0 1 DAK1
0 0 1 0 DAK2
0 0 1 1 DAK3
0 1 0 0 DAK4
0 1 0 1 DAK5
0 1 1 0 DAK6
0 1 1 1 DAK7
1 0 0 0 DAK8
1 0 0 1 DAK9
1 0 1 0 DAK10
1 0 1 1 DAK11
1 1 0 0 DAK12
1 1 0 1 DAK13
1 1 1 0 DAK14
1 1 1 1 DAK15
0 0 0 0 Last DAK released

The DAK actions are configured from Direct Access Key Settings.

The input matrix function require Turbine software 4.7 or later.